The Laryngoscope · 2021

To Pack a Nose: High-Fidelity Epistaxis Simulation Using 3D Printing Technology.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gao Rebecca W, Rooney Deborah, Harvey Rebecca, Malloy Kelly M, VanKoevering Kyle K

Аннотация

BACKGROUND: Initial management and stabilization of epistaxis is managed by a diverse offset of clinical providers with variable levels of training.

OBJECTIVE: To determine the anatomic and clinical fidelity and ease of use of a novel simulator for the training and assessment of epistaxis management skills.

STUDY DESIGN: Qualitative Research Study using expert questionnaire's for validation of a newly developed simulator.

METHODS: We performed a quasi-experimental intervention with 22 otolaryngology faculty and 10 trainees who independently evaluated the simulator. Data were collected in three phases: phase 1 (preliminary evaluation), phase 2 (final expert evaluation), and phase 3 (trainee evaluation). We designed a three-dimensional (3D) printed model from a de-identified patient computed tomography scan. Artificial blood was circulated through catheters to simulate bleeding from three distinct sites (sphenopalatine, Kiesselbach's plexus, and anterior ethmoid). Four domains were assessed: "Physical and anatomic attributes," "Realism of experience," "Ability to perform tasks," and "Value and clinical relevance." Internal structure and validity were measured with Cronbach's alpha and item outfit mean-square statistics.

RESULTS: Results from otolaryngology faculty showed very high median ratings for "Value of the simulator as a training tool" (4.0/4) and high ratings for "Relevance to practice" (4.0/4), and realism of experience (4.0/4). Responses from otolaryngology trainees demonstrated high value for clinical training (4.0/4) and high likelihood to recommend use for future trainees (4.0/4). Confidence in managing epistaxis before (1.0/4) and after (3.0/4) simulator use was statistically improved (P = .03).

CONCLUSIONS: Using 3D printing technology, we created a novel simulator for epistaxis management. Preliminary evidence suggests the model is cost-effective, anatomically realistic, relevant to trainees' educational needs, and valuable as a training tool.

LEVEL OF EVIDENCE: 3 Laryngoscope, 132:747-753, 2022.