DOI 10.1002/mdc3.14160

Медицинская библиотека · Movement disorders clinical practice · 2024

Estimating Disability in Patients with Essential Tremor: Comparison of Tremor Rating Scale, Spiral Drawing, and Accelerometric Tremor Power.

Hollý Petr, Hubená Tereza, Čihák Martin, Pavlíková Aneta, Kemlink David, Ulmanová Olga, Rusz Jan, Jech Robert, Krupička Radim, Růžička Evžen

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Although performance rating scales, spiral drawing, water pouring, and accelerometry are commonly used to assess tremor severity, the extent to which their results correlate with impairment in activities of daily living (ADL) remains unclear.

OBJECTIVE

The aim was to identify the most effective predictors of ADL in essential tremor (ET).

METHODS

Forty ET patients were examined using The Essential Tremor Rating Assessment Scale (TETRAS), spiral drawing, volume of water spilled, and accelerometric tremor power. Root-mean-square error, R2, and F-test were calculated for models predicting TETRAS ADL subscore.

RESULTS

TETRAS Performance Subscale explained the variability in TETRAS ADL with an R2 value of 0.686. Models incorporating spiral rating and accelerometric tremor power (R2 = 0.731) and water spillage volume (R2 = 0.756) were not statistically superior.

CONCLUSIONS

TETRAS performance subscore predicted nearly 70% ADL impairment in ET patients. Incorporating the spiral rating, accelerometric tremor power, and water pouring test did not enhance ADL estimation.

Для цитирования: Hollý Petr, Hubená Tereza, Čihák Martin, Pavlíková Aneta, Kemlink David, Ulmanová Olga, Rusz Jan, Jech Robert, Krupička Radim, Růžička Evžen. Estimating Disability in Patients with Essential Tremor: Comparison of Tremor Rating Scale, Spiral Drawing, and Accelerometric Tremor Power.. Movement disorders clinical practice. 2024. DOI: 10.1002/mdc3.14160.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.