MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/s0102-86502006000600004

Медицинская библиотека · Acta cirurgica brasileira · 2006

[Right-to-left shunt determination in dog lungs under inhalation anesthesia with rebreathing and non-rebreathing system].

Rosa André Leguthe, Mota Patrícia Cristina Azevedo, Castiglia Yara Marcondes Machado

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To investigatge right-to-left shunt determination in dog lungs under inhalantion anesthesia with non-rebreathing and rebreathing systems and fraction of inspired oxygen (F I O2) of 0.9 and 0.4, respectively.

METHODS

Two groups of 10 dogs each under inhalation anesthesia with sevoflurane: GI in which it was utilized non-rebreathing semiclosed system and F I O2 = 0.9, and GII in which it was utilized rebreathing semiclosed system and F I O2 = 0.4. The study parameters were: heart rate, medium arterial pressure, right-to-left intrapulmonary shunt, hematocrit, hemoglobin, arterial partial pressure of oxygen, mixed venous partial pressure of oxygen, mixed venous oxygen saturation, arterial partial pressure of carbon dioxide, partial pressure of water in the alveoli.

RESULTS

Shunt results were significantly different between the two groups - GI data were higher than GII in all the evaluated moments. Hence, the group with nonrebreathing (GI) developed a superior grade of intrapulmonary shunt when compared with the rebreathing group (GII). The partial pressure of water in the alveoli was significantly higher in GII.

CONCLUSION

The inhalation anesthesia with non-rebreathing system and F I O2 = 0.9 developed a higher grade of intrapulmonary right-to-left shunt when compared with the rebreathing system and F I O2 = 0.4. The higher humidity in GII contributed to the result.

Для цитирования: Rosa André Leguthe, Mota Patrícia Cristina Azevedo, Castiglia Yara Marcondes Machado. [Right-to-left shunt determination in dog lungs under inhalation anesthesia with rebreathing and non-rebreathing system].. Acta cirurgica brasileira. 2006. DOI: 10.1590/s0102-86502006000600004.