MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2004.08.059

Медицинская библиотека · Journal of the American College of Cardiology · 2004

Comparative accuracy of real-time myocardial contrast perfusion imaging and wall motion analysis during dobutamine stress echocardiography for the diagnosis of coronary artery disease.

Elhendy Abdou, O'Leary Edward L, Xie Feng, McGrain Anna C, Anderson James R, Porter Thomas R

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study sought to compare the accuracy of myocardial contrast echocardiography (MCE) and wall motion analysis (WMA) during submaximal and peak dobutamine stress echocardiography (DSE) for the diagnosis of coronary artery disease (CAD).

BACKGROUND

The relative merits of MCE and WMA for the detection of CAD during DSE have not been studied in a large number of patients.

METHODS

We studied 170 patients who underwent dobutamine (up to 50 microg/kg/min)-atropine stress testing and coronary angiography. The WMA and MCE (using repeated boluses of Optison [Mallinckrodt, St. Louis, Missouri] or Definity [Bristol-Myers Squibb, New York, New York]) were performed at rest, at intermediate stress (65% to 75% of maximal heart rate), and at peak stress. The diagnosis of CAD (>/=50% stenosis in >/=1 coronary artery) was based on reversible wall motion and perfusion abnormalities.

RESULTS

Coronary artery disease was detected in 127 (75%) patients. Sensitivity of MCE was higher than that of WMA at maximal stress (91% vs. 70%; p = 0.001) and at intermediate stress (84% vs. 20%; p = 0.0001). Specificity was lower for MCE compared with WMA (51% vs. 74%; p = 0.01). Overall accuracy was higher for MCE than for WMA (81% vs. 71%; p = 0.01). Sensitivity for detection of CAD based on abnormalities in >/=2 vascular regions was higher for MCE than for WMA (67% vs. 28%; p < 0.01).

CONCLUSIONS

The majority of inducible perfusion abnormalities occur at an intermediate phase of the stress test, without wall motion abnormalities. Myocardial contrast echocardiography provides better sensitivity than WMA, particularly in patients with submaximal stress and in identifying patients with multivessel CAD.

Для цитирования: Elhendy Abdou, O'Leary Edward L, Xie Feng, McGrain Anna C, Anderson James R, Porter Thomas R. Comparative accuracy of real-time myocardial contrast perfusion imaging and wall motion analysis during dobutamine stress echocardiography for the diagnosis of coronary artery disease.. Journal of the American College of Cardiology. 2004. DOI: 10.1016/j.jacc.2004.08.059.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.