Intravenous nitroglycerin for intrapartum internal podalic version of the second non-vertex twin.

Dufour P, Vinatier D, Vanderstichèle S, Subtil D, Ducloy J C, Puech F, Codaccionni X, Monnier J C

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Authors report their experience of intravenous nitroglycerin as uterine relaxing agent for managing successfully internal podalic version of the second twin.

METHODS

From a retrospective study including nine observations of internal podalic version of the second non vertex twin performed with administration of intravenous nitroglycerin, between August 1994 and February 1996, authors compare their results with those reported elsewhere.

RESULTS

Two failures of internal podalic version with nitroglycerin have been observed. But one failure is not considered to be due to the NTG: it was a patient, who had a panic attack necessitating a general anesthesia for sedative purpose. The internal podalic version succeeded. The true failure of NTG needed an emergency cesarean due to acute fetal distress and a non relaxing uterus. One internal podalic version was complicated by hemorrhage. The intravenous NTG used to induce uterine atonia associated with epidural-analgesia to relief pain avoiding general anesthesia makes internal podalic version easier.

CONCLUSION

Our results confirmed those already reported. That intravenous nitroglycerin (NTG) injection induces a transient and prompt uterine relaxation required for internal podalic version without affecting maternal and fetal prognosis.

Для цитирования: Dufour P, Vinatier D, Vanderstichèle S, Subtil D, Ducloy J C, Puech F, Codaccionni X, Monnier J C. Intravenous nitroglycerin for intrapartum internal podalic version of the second non-vertex twin.. European journal of obstetrics, gynecology, and reproductive biology. 1996. DOI: 10.1016/s0301-2115(96)02537-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.