MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aor.14135

Медицинская библиотека · Artificial organs · 2021

Oxygenated versus non-oxygenated flush out and storage of donor livers: An experimental study.

Brüggenwirth Isabel M A, van der Plas Willemijn S, van Leeuwen Otto B, Thorne Adam M, Rayar Michel, de Meijer Vincent E, Porte Robert J

СтатьяПеревод в очереди

Аннотация

BACKGROUND

During donor organ procurement and subsequent static cold storage (SCS), hepatic adenosine triphosphate (ATP) levels are progressively depleted, which contributes to ischemia-reperfusion injury (IRI). We sought to investigate a simple approach to prevent ATP depletion and IRI using a porcine donation after circulatory death (DCD) liver reperfusion model.

METHODS

After 30 min warm ischemia, porcine livers were flushed via the portal vein with cold (4°C) non-oxygenated University of Wisconsin (UW) preservation solution (n = 6, control group) or with oxygenated UW (n = 6, OxyFlush group). Livers were then subjected to 4 h SCS in non-oxygenated (control) or oxygenated (OxyFlush) UW, followed by 4 h normothermic reperfusion using whole blood. Hepatic ATP levels were compared, and hepatobiliary function and injury were assessed.

RESULTS

At the end of SCS, ATP was higher in the OxyFlush group compared to controls (delta ATP of +0.26 vs. -0.68 µmol/g protein, p = 0.04). All livers produced bile and metabolized lactate, and there were no differences between the groups. Grafts in the OxyFlush group had lower blood glucose levels after reperfusion (p = 0.04). Biliary pH, glucose and bicarbonate were not different between the groups. Injury markers including liver transaminases, lactate dehydrogenase, malondialdehyde, cell-free DNA and flavin mononucleotide in the SCS solution and during reperfusion were also similar. Histological assessment of the parenchyma and bile ducts did not reveal differences between the groups.

CONCLUSION

Oxygenated flush out and storage of DCD porcine livers prevents ATP depletion during ischemia, but this does not seem sufficient to mitigate early signs of IRI.

Для цитирования: Brüggenwirth Isabel M A, van der Plas Willemijn S, van Leeuwen Otto B, Thorne Adam M, Rayar Michel, de Meijer Vincent E, Porte Robert J. Oxygenated versus non-oxygenated flush out and storage of donor livers: An experimental study.. Artificial organs. 2021. DOI: 10.1111/aor.14135.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.