A Novel Device for Closed Reduction and Percutaneous Fixation of Thoracolumbar Fractures.

Linhart Christoph, Becker Christopher A, Befrui Nima, Suero Eduardo M, Kussmaul Adrian C, Böcker Wolfgang, Kammerlander Christian, Greiner Axel

СтатьяПеревод в очереди

Аннотация

BACKGROUND/AIM: Open surgical reduction/fixation of thoracolumbar fractures results in significant soft-tissue trauma and related complications. Minimally-invasive technical developments could deliver similar radiological outcomes, while avoiding the related complications. We evaluated radiological and perioperative outcomes in thoracolumbar fractures by using a novel minimally-invasive device.

PATIENTS AND

METHODS

Twenty-six patients with 29 thoracolumbar fractures using the NForce device were analyzed. Postoperative reduction and alignment were assessed by radiographic measurement of the local kyphosis angle (LKA) up until a follow-up period of 9 months.

RESULTS

Postoperative imaging revealed an average reduction of traumatic kyphosis of 8.25° (±7.72°) with an average postoperative LKA of 3.24° (±8.97°). The highest degree of reduction was 27.39°. The mean LKA had increased to 5.08° (±5.17°) at 3 months postoperative, 5.43° (±4.32°) at 6 months and 6.21° (±3.82°) at 9 months.

CONCLUSION

The minimally invasive NForce system is effective in performing anatomic percutaneous reduction/fixation.

Для цитирования: Linhart Christoph, Becker Christopher A, Befrui Nima, Suero Eduardo M, Kussmaul Adrian C, Böcker Wolfgang, Kammerlander Christian, Greiner Axel. A Novel Device for Closed Reduction and Percutaneous Fixation of Thoracolumbar Fractures.. In vivo (Athens, Greece). 2022. DOI: 10.21873/invivo.12715.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.