Journal of prosthodontics : official journal of the American College of Prosthodontists · 2009

Effect of surface preparation on the failure load of a highly filled composite resin bonded to a denture base resin.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shimizu Hiroshi, Kawaguchi Tomohiro, Yoshida Kaneyoshi, Tsue Fumitake, Takahashi Yutaka

Аннотация

PURPOSE: The purpose of this study was to evaluate the effect of the surface preparation on the maximum fracture load value of a highly filled gingival shade composite resin bonded to a denture base resin.

MATERIALS AND METHODS: Block specimens were prepared from a heat-processed denture base resin and divided into five groups. The flat surfaces of the specimens were abraded with 400-grit silicon carbide paper, then prepared in one of the following ways: (1) without preparation (group 1); (2) application of silane coupling agent (group 2); (3) application of dichloromethane (group 3); (4) application of dichloromethane following the silane coupling agent (group 4); or (5) tribochemical silica coating (group 5). A highly filled gingival shade composite resin was applied (area diameter= 5 mm) and polymerized with a light polymerizing unit. Specimens made entirely of heat-processed denture base resin were also fabricated as references (group 6). The halves of the specimens of groups 4, 5, and 6 were thermocycled up to 10,000 times in water between 5 degrees C and 55 degrees C with a 1-minute dwell time at each temperature. Shear testing was performed in a universal testing machine at a crosshead speed of 1 mm/min, and the maximum fracture load values were determined (n = 10).

RESULTS: The maximum fracture load values of the highly filled gingival shade composite resin bonded to the denture base resin for all preparation groups were significantly enhanced before thermocycling (p < 0.05). Group 5 exhibited the greatest fracture load value, followed by group 4, compared to the other groups (p < 0.05), however, the fracture load values significantly decreased for these groups after thermocycling (p < 0.05), whereas the fracture load value of group 6 did not decrease (p > 0.05).

CONCLUSIONS: Tribochemical silica coating and the application of dichloromethane after the silane coupling agent were effective surface preparations for the bonding of a highly filled gingival shade composite resin to a denture base resin, however, the bond durability of these treatments may be insufficient.