MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0956462417717649

Медицинская библиотека · International journal of STD & AIDS · 2017

An evaluation of the SD Bioline HIV/syphilis duo test.

Holden Jeffrey, Goheen Joshua, Jett-Goheen Mary, Barnes Mathilda, Hsieh Yu-Hsiang, Gaydos Charlotte A

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

Many health agencies now recommend routine HIV and syphilis testing for pregnant women and most-at-risk populations such as men who have sex with men. With the increased availability of highly sensitive, low cost rapid point-of-care tests, the ability to meet those recommendations has increased, granting wider access to quick and accurate diagnoses. Using blood specimens collected from a Baltimore City Health Department (BCHD) sexually transmitted infection clinic, we evaluated the SD Bioline HIV/Syphilis Duo, a rapid test that simultaneously detects antibodies to HIV and syphilis and has the potential to further benefit clinics and patients by reducing costs, testing complexity, and patient wait times. SD DUO HIV sensitivity and specificity, when compared to BCHD results, were 91.7 and 99.5%, respectively. SD DUO syphilis sensitivity and specificity, when compared to rapid plasma reagin, were 85.7 and 96.8%, respectively, and 69.7 and 99.7%, respectively, when compared to Treponema pallidum particle agglutination (TPPA). SD DUO syphilis sensitivity and specificity, when compared to a traditional screening algorithm, improved to 92.3 and 100%, respectively, and improved to 72.9 and 99.7%, respectively, when compared to a reverse screening algorithm. The HIV component of the SD DUO performed moderately well. However, results for the SD DUO syphilis component, when compared to TPPA, support the need for further testing and assessment.

Для цитирования: Holden Jeffrey, Goheen Joshua, Jett-Goheen Mary, Barnes Mathilda, Hsieh Yu-Hsiang, Gaydos Charlotte A. An evaluation of the SD Bioline HIV/syphilis duo test.. International journal of STD & AIDS. 2017. DOI: 10.1177/0956462417717649.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.