MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2460/javma.24.09.0586

Медицинская библиотека · Journal of the American Veterinary Medical Association · 2024

Epicardial pacemaker placement in cats is associated with resolution of clinical signs and excellent quality of life.

Rossanese Matteo, Brockman Dan, Chanoit Guillaume, Scott Peter, de la Puerta Benito, Crosland Andrew, Dukes-McEwan Joanna, Basili Mattia

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To describe complications and outcomes in cats undergoing epicardial pacemaker (EP) implantation for artificial cardiac pacing and to investigate improvement in clinical signs and health-related quality of life (HRQoL) following surgery.

METHODS

39 client-owned cats that underwent EP placement. Medical records of 4 UK-based referral hospitals were searched and data reviewed retrospectively between July 2010 and December 2022. An HRQoL questionnaire was used to assess outcomes and HRQoL.

RESULTS

The primary reasons for referral included collapsing episodes (n = 27) and bradycardia (31). Third-degree atrioventricular block (29 of 39) was the predominant indication for pacemaker placement. Intra- and postoperative complications were documented in 3 of 39 and 14 of 39 cats, respectively. All cats survived to discharge, and median follow-up time was 719 days (range, 9 to 2,285 days). Owners reported improvement in clinical signs, high level of satisfaction, and improved HRQoL.

CONCLUSIONS

Epicardial pacemaker placement effectively resolves clinical signs of bradyarrhythmias in cats, leading to significant improvements in HRQoL. Postoperative complications are common but do not impact the overall outcome. Cats undergoing EP placement have an excellent HRQoL with an improvement in clinical signs and a high level of owner satisfaction.

CLINICAL RELEVANCE: Epicardial pacemaker placement is the current method of choice for cats showing clinical signs and requiring artificial cardiac pacing. Despite the occurrence of postoperative complications, these did not adversely impact overall outcomes, with high owner satisfaction reported.

Для цитирования: Rossanese Matteo, Brockman Dan, Chanoit Guillaume, Scott Peter, de la Puerta Benito, Crosland Andrew, Dukes-McEwan Joanna, Basili Mattia. Epicardial pacemaker placement in cats is associated with resolution of clinical signs and excellent quality of life.. Journal of the American Veterinary Medical Association. 2024. DOI: 10.2460/javma.24.09.0586.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.