OBJECTIVE

This study evaluated the effect of application delays on the dentin bond strength of different adhesive systems used in composite restorations.

METHODS

Forty-five extracted human molars were randomly assigned to Clearfil SE Bond, G-Premio Bond, and Single Bond Universal (n = 15). Each adhesive was subdivided according to application time: immediate use, 3-minute delay, and 5-minute delay (n = 5). Adhesives were applied to occlusal dentin surfaces according to manufacturers' instructions, followed by composite build-up procedures. Microtensile bond strength (µTBS) was evaluated using a universal testing machine, and failure modes were examined microscopically. Selected specimens were analyzed using scanning electron microscopy (SEM).

RESULTS

Adhesive system (F = 48.32, p < 0.001) and application time (F = 22.72, p < 0.001) significantly influenced µTBS. The highest bond strength was observed in the immediate Clearfil SE Bond group (34.5 ± 4.8 MPa), whereas the lowest value was recorded in the 5-minute delayed G-Premio Bond group (13.4 ± 2.8 MPa). A 5-minute delay significantly reduced bond strength in all adhesive systems, whereas a 3-minute delay generally did not affect bonding performance. More than 85% adhesive failures were observed in the 5-minute delay groups. SEM analysis revealed porosity and crater-like surface defects in delayed universal adhesive groups.

CONCLUSIONS

A 5-minute application delay significantly compromised dentin bond strength and increased adhesive failures. Immediate adhesive application is recommended to preserve bonding effectiveness and optimize restoration longevity.

Для цитирования: Gültekin Ahmet, Bayraktar Nilay, Harorlı Osman Tolga. Effect of application delays on the dentin bond strength and interfacial morphology of different adhesive systems: an SEM analysis.. BMC oral health. 2026. DOI: 10.1186/s12903-026-09596-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.