MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.eururo.2019.06.003

Медицинская библиотека · European urology · 2019

Robotic Renal Artery Aneurysm Repair.

Abreu Andre Luis, Medina Luis G, Chopra Sameer, Gill Karanvir, Cacciamani Giovanni E, Azhar Raed A, Ashrafi Akbar, Winter Matthew, Fay Carlos, Weaver Fred, Duddalwar Vinay, Desai Mihir, Sotelo Rene, Gill Inderbir S

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Renal artery aneurysm (RAA) is a rare condition, traditionally managed with endovascular or open surgical techniques.

OBJECTIVE

To report our experience with robotic RAA repair.

DESIGN, SETTING, AND

PARTICIPANTS

Nine consecutive patients underwent intracorporeal robotic surgery for 10 RAAs.

SURGICAL PROCEDURE: Two patients underwent concomitant robotic partial nephrectomy. One patient had RAA in a solitary kidney. Median RAA diameter was 2.2 (1.8-3)cm. Intracorporeal transarterial hypothermic renal perfusion was performed in five patients. Robotic techniques included tailored aneurysmectomy and repair (n=5), excision with end-to-end anastomosis (n=2), aneurysmectomy with branch reimplantation (n=1), prosthetic interposition graft repair (n=1), and simple nephrectomy (n=1; this patient's data were excluded from analysis).

MEASUREMENTS: Demographics, RAA characteristics, intraoperative techniques, perioperative outcomes, and follow up data were analyzed. Aneurysms were diagnosed by computed tomography, angiography, or incidentally during the performance of a partial nephrectomy.

RESULTS AND LIMITATIONS: All cases were performed robotically, without conversion to open surgery. Median (range) operative time was 3.8 (3-6)h, warm ischemia time 26 (19-32)min, hypothermic renal perfusion time 34 (29-69)min, and estimated blood loss 100 (25-400)ml. No intraoperative blood transfusion was required. Median hospital stay was 3 (2-6)d. One patient had a Clavien-Dindo grade II complication. At median follow-up of 16 (2-67)mo, all patients had preserved renal function. Follow-up imaging confirmed normal caliber reconstructed renal arteries with globally perfused kidneys, except for two kidneys with small segmental infarcts due to an intentionally ligated small polar vessel. Limitations include the small number of patients and the retrospective nature of the study.

CONCLUSIONS

Robotic repair of complex RAAs is feasible. Surgical expertise, patient selection, and RAA-specific vascular reconstruction are critical for success. Greater experience is needed to evaluate the proper place of robotic repair of RAAs.

PATIENT SUMMARY: We report intracorporeal robotic repair for complex renal artery aneurysms. This robotic operation is feasible and safe, and replicates open principles. However, it requires considerable experience and expertise.

Для цитирования: Abreu Andre Luis, Medina Luis G, Chopra Sameer, Gill Karanvir, Cacciamani Giovanni E, Azhar Raed A, Ashrafi Akbar, Winter Matthew, Fay Carlos, Weaver Fred, Duddalwar Vinay, Desai Mihir, Sotelo Rene, Gill Inderbir S. Robotic Renal Artery Aneurysm Repair.. European urology. 2019. DOI: 10.1016/j.eururo.2019.06.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.