Interatrial defect sizing by intracardiac and transesophageal echocardiography compared with fluoroscopic measurements in patients undergoing percutaneous transcatheter closure.

Boccalandro Fernando, Muench Andreas, Salloum Joseph, Awadalla Hany, Carter Catherine, Barasch Eddy, Smalling Richard W

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

The purpose of this study was to evaluate prospectively the feasibility and accuracy of using echocardiographic measurements by transesophageal and intracardiac echocardiography (TEE and ICE, respectively) for interatrial septal defect sizing during percutaneous transcatheter closure. Forty-two patients underwent balloon sizing of interatrial septal defects using TEE in 21 of them and ICE in the other half. These measurements were correlated with quantitative fluoroscopic analysis and evaluated for bias and agreement between methods using a Bland-Altman analysis. Echocardiographic measurements were obtained by ICE and TEE in all patients. An excellent correlation was found between TEE and quantitative fluoroscopy (r = 0.898; P < 0.001) and between ICE and quantitative fluoroscopy (r = 0.876; P < 0.001), with a significant agreement (P < 0.001) and minimal positive bias toward the echocardiographic measurements. Both TEE and ICE are excellent methods of interatrial defect sizing when compared with quantitative fluoroscopic measurements.

Для цитирования: Boccalandro Fernando, Muench Andreas, Salloum Joseph, Awadalla Hany, Carter Catherine, Barasch Eddy, Smalling Richard W. Interatrial defect sizing by intracardiac and transesophageal echocardiography compared with fluoroscopic measurements in patients undergoing percutaneous transcatheter closure.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2004. DOI: 10.1002/ccd.20082.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.