MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/ch-179224

Медицинская библиотека · Clinical hemorheology and microcirculation · 2017

Postoperative control of functional muscle flaps for facial palsy reconstruction: Ultrasound guided tissue monitoring using contrast enhanced ultrasound (CEUS) and ultrasound elastography.

Kehrer Andreas, Mandlik Veronika, Taeger Christian, Geis Sebastian, Prantl Lukas, Jung Ernst-Michael

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Facial paralysis causes excruciating impairments including facial asymmetry, limited eye closure, oral incontinence and social dysfunction. Modern plastic surgical reconstructions render favorable results with well-perfused dynamic muscle flaps. Post-operative tissue monitoring is a critical determinant for success. Contrast-enhanced Ultrasound (CEUS) and elastography have proven superior properties to evaluate tissue perfusion in various organs. We evaluated their role for functional muscle flaps positioned at the sub-skin level in facial palsy patients.

METHODS

From 2016-2017 five patients received muscle flap reconstructions. Flaps included four free transplants and one pedicled transfer. Postoperatively tissue vitality and blood flow were assessed with CEUS. One experienced examiner using linear probes (6-9, 6-15 MHz) and bolus injections of Sulphur-hexafluoride microbubbles evaluated tissue perfusion. Using the time intensity curve- (TIC)-analysis measurements were recorded for TTP (time to peak) and AUC (Area under curve). Tissue elasticity was assessed with ultrasound elastography.

RESULTS

All flaps were successful and showed no major complications. TTP-values in flap tissue showed slightly decreased values of 35.12±33.99 s and 25.04±10.86 s compared to surrounding tissue with 19.88±6.94 s. AUC-analysis however revealed higher values of 292.25±169.52 RU and 274.51±115.88 RU than surrounding tissue with 150.90±40.21 RU. Elastography demonstrated predominantly elastic flap tissue whereas surrounding tissue confirmed a slightly harder tissue quality. CEUS in combination with elastography verified tissue vitality and blood flow in a safe and reproducible manner.

CONCLUSIONS

Post-operative perfusion monitoring in muscle flaps positioned at a sub-skin level may be performed superiorly by CEUS and elastography in a quick, reproducible and minimally-invasive fashion.

Для цитирования: Kehrer Andreas, Mandlik Veronika, Taeger Christian, Geis Sebastian, Prantl Lukas, Jung Ernst-Michael. Postoperative control of functional muscle flaps for facial palsy reconstruction: Ultrasound guided tissue monitoring using contrast enhanced ultrasound (CEUS) and ultrasound elastography.. Clinical hemorheology and microcirculation. 2017. DOI: 10.3233/ch-179224.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.