MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0753-9053(88)80044-9

Медицинская библиотека · Annales de chirurgie de la main : organe officiel des societes de chirurgie de la main · 1988

Fractures and non unions of the proximal pole of the carpal scaphoid bone. Internal fixation by a proximal to distal screw.

Alnot J Y, Bellan N, Oberlin C, De Cheveigné C

СтатьяПеревод в очереди

Аннотация

We report a new proximal to distal screw fixation technique for proximal pole fractures and non unions of the carpal scaphoid (type I of the Schernberg, Elzein and Gerard classification). Seven cases of non union with a live proximal polar fragment were operated from 1984 to 1986 with 4 excellent and 2 fair results and one failure. Three recent displaced fractures were also treated this way, with 3 excellent results. This useful technique is worth knowing and deserves a place in the treatment of scaphoid fractures, especially type I proximal pole fractures which represent a challenging problem, and are in no way comparable to other locations.

Для цитирования: Alnot J Y, Bellan N, Oberlin C, De Cheveigné C. Fractures and non unions of the proximal pole of the carpal scaphoid bone. Internal fixation by a proximal to distal screw.. Annales de chirurgie de la main : organe officiel des societes de chirurgie de la main. 1988. DOI: 10.1016/s0753-9053(88)80044-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.