DOI 10.1038/s41598-023-39352-7

Медицинская библиотека · Scientific reports · 2023

3D assessment of the nasolabial region in cleft models comparing an intraoral and a facial scanner to a validated baseline.

Olmos Manuel, Matta Ragai, Buchbender Mayte, Jaeckel Fabian, Nobis Christopher-Philipp, Weber Manuel, Kesting Marco, Lutz Rainer

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

We aimed to validate the metric accuracy of a 3-dimensional (3D) facial scanner (FS) and an intraoral scanner (IOS) in capturing the nasolabial region in ex vivo unilateral cleft lip and palate (UCLP) models. The nasolabial region of 10 UCLP models was scanned using a 3D FS as well as an IOS and a previously validated stationary 3D scanner as a reference. Intraoral scan was performed directly on the UCLP models. In order to apply the FS on the models, they were embedded in a 3D printed sample face. Both test groups were aligned to the reference by applying a section-based best-fit algorithm. Subsequent analysis of the metric deviation from the reference was performed with a 3D analysis tool. Mean distance and integrated distance served as main parameters for surface and volume comparison. Point comparison served as an additional parameter. Statistical analysis was carried out using t-test for unconnected samples. Considering mean distance and integrated distance as main parameters for 3D evaluation of the scanner's accuracy, FS and IOS differ significantly in their metric precision in scanning the cleft model compared to the reference. The IOS proved to be significantly more accurate than the FS compared to the previously described stationary 3D scanner as reference and validated baseline. Further validation of the tested IOS and FS for 3D assessment of the nasolabial region is presented by adding the previously validated ATOS III Triple Scan blue light scanner as a reference. The IOS shows, compared to a validated baseline scan, significantly higher metric precision in experimental cleft model scanning. The collected data provides a basis for clinical application of the IOS for 3D assessment of the nasolabial region.

Для цитирования: Olmos Manuel, Matta Ragai, Buchbender Mayte, Jaeckel Fabian, Nobis Christopher-Philipp, Weber Manuel, Kesting Marco, Lutz Rainer. 3D assessment of the nasolabial region in cleft models comparing an intraoral and a facial scanner to a validated baseline.. Scientific reports. 2023. DOI: 10.1038/s41598-023-39352-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.