MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00005131-199901000-00007

Медицинская библиотека · Journal of orthopaedic trauma · 1999

Should distal interlocking of tibial nails be performed from a medial or a lateral direction? anatomical and biomechanical considerations.

Roberts C S, King D, Wang M, Seligson D, Voor M J

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To compare the relative risks of neurovascular injury from perforation during distal interlocking and the biomechanical stability of two approaches to distal interlocking of tibial nails.

DESIGN

In vitro anatomical and biomechanical study.

SETTING

All mechanical testing was performed in a servohydraulic test frame with a customized motion transducer.

INTERVENTION: Tibial nails were interlocked distally with a medial-to-lateral (ML) or a lateral-to-medial (LM) approach.

MAIN OUTCOME MEASURE: The distances from the nearest end of each distal locking screw to four neurovascular structures were measured manually with calipers, and two-dimensional motion under simulated stance load across the fracture site was recorded.

RESULTS

There were greater distances from the posterior tibial neurovascular bundle and the superficial peroneal nerve with distal targeting from the LM direction compared with targeting from the ML direction. Biomechanically, the ML nail configuration demonstrated slightly greater resistance to bending than the LM configuration.

CONCLUSIONS

Distal tibial interlocking from the LM direction appears to be safer than interlocking from the ML direction with regard to relative distances from the neurovascular structures. This small anatomical advantage must be considered in light of slightly greater resistance to bending of the ML interlocking configuration compared with the LM interlocking configuration.

Для цитирования: Roberts C S, King D, Wang M, Seligson D, Voor M J. Should distal interlocking of tibial nails be performed from a medial or a lateral direction? anatomical and biomechanical considerations.. Journal of orthopaedic trauma. 1999. DOI: 10.1097/00005131-199901000-00007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.