MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacep.2024.01.017

Медицинская библиотека · JACC. Clinical electrophysiology · 2024

Impact of Left Atrial Posterior Wall Ablation During Pulsed-Field Ablation for Persistent Atrial Fibrillation.

Turagam Mohit K, Neuzil Petr, Schmidt Boris, Reichlin Tobias, Neven Kars, Metzner Andreas, Hansen Jim, Blaauw Yuri, Maury Philippe, Arentz Thomas, Sommer Philipp, Anic Ante, Anselme Frederic, Boveda Serge, Deneke Tom, Willems Stephan, van der Voort Pepijn, Tilz Roland, Funasako Moritoshi, Scherr Daniel, Wakili Reza, Steven Daniel, Kautzner Josef, Vijgen Johan, Jais Pierre, Petru Jan, Chun Julian, Roten Laurent, Füting Anna, Lemoine Marc D, Ruwald Martin, Mulder Bart A, Rollin Anne, Lehrmann Heiko, Fink Thomas, Jurisic Zrinka, Chaumont Corentin, Adelino Raquel, Nentwich Karin, Gunawardene Melanie, Ouss Alexandre, Heeger Christian-Hendrik, Manninger Martin, Bohnen Jan-Eric, Sultan Arian, Peichl Petr, Koopman Pieter, Derval Nicolas, Kueffer Thomas, Reinsch Nico, Reddy Vivek Y

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury.

OBJECTIVES

This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA).

METHODS

In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events.

RESULTS

Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51).

CONCLUSIONS

In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.

Для цитирования: Turagam Mohit K, Neuzil Petr, Schmidt Boris, Reichlin Tobias, Neven Kars, Metzner Andreas, Hansen Jim, Blaauw Yuri, Maury Philippe, Arentz Thomas, Sommer Philipp, Anic Ante, Anselme Frederic, Boveda Serge, Deneke Tom, Willems Stephan, van der Voort Pepijn, Tilz Roland, Funasako Moritoshi, Scherr Daniel, Wakili Reza, Steven Daniel, Kautzner Josef, Vijgen Johan, Jais Pierre, Petru Jan, Chun Julian, Roten Laurent, Füting Anna, Lemoine Marc D, Ruwald Martin, Mulder Bart A, Rollin Anne, Lehrmann Heiko, Fink Thomas, Jurisic Zrinka, Chaumont Corentin, Adelino Raquel, Nentwich Karin, Gunawardene Melanie, Ouss Alexandre, Heeger Christian-Hendrik, Manninger Martin, Bohnen Jan-Eric, Sultan Arian, Peichl Petr, Koopman Pieter, Derval Nicolas, Kueffer Thomas, Reinsch Nico, Reddy Vivek Y. Impact of Left Atrial Posterior Wall Ablation During Pulsed-Field Ablation for Persistent Atrial Fibrillation.. JACC. Clinical electrophysiology. 2024. DOI: 10.1016/j.jacep.2024.01.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.