Safety and efficacy of cerebral embolic protection in transcatheter aortic valve implantation: an updated meta-analysis.

Tan Nicholas, Fei Gao, Rizwan Amanullah Mohammed, Lim Soo Teik, Abdul Aziz Zameer, Govindasamy Sivaraj, Chao Victor Tar Toong, Ewe See Hooi, Ho Kay Woon, Yap Jonathan

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The use of cerebral embolic protection devices during transcatheter aortic valve implantation (TAVI) reveals conflicting data.

AIMS: This updated meta-analysis aims to evaluate the efficacy and safety of the SENTINEL Cerebral Protection System.

METHODS

A literature search for relevant studies up to September 2022 was performed. Study outcomes were divided based on time period - overall (up to 30 days) and short (≤7 days). The outcomes studied include stroke (disabling, non-disabling), mortality, neuroimaging findings, transient ischaemic attack, acute kidney injury and major vascular and bleeding complications.

RESULTS

A total of 15 studies involving 294,134 patients were included. Regarding overall outcomes, significant reductions were noted for mortality (odds ratio [OR] 0.60, 95% confidence interval [CI]: 0.41-0.88; p=0.008), all stroke (OR 0.64, 95% CI: 0.46-0.88; p=0.006) and disabling stroke (OR 0.42, 95% CI: 0.23-0.74; p=0.003) using the SENTINEL device. No significant differences were noted for other outcomes. There was significant heterogeneity across the studies for mortality (p=0.013) and all stroke (p=0.003). Including only randomised data (n=4), there was only significant reduction in the incidence of disabling stroke (OR 0.39, 95% CI: 0.17-0.89; p=0.026) in the SENTINEL group. In studies reporting ≤7-day outcomes (n=8), use of the SENTINEL device demonstrated significantly lower rates of all stroke (p<0.001), disabling stroke (p<0.001) and major bleeding complications (p=0.02). No differences in neuroimaging outcomes were noted.

CONCLUSIONS

In this updated meta-analysis, use of the SENTINEL Cerebral Protection System was associated with lower rates of mortality, all stroke and disabling stroke, although significant heterogeneity was noted for mortality and all stroke. Including exclusively randomised data, there was only significant reduction in the incidence of disabling stroke. No significant adverse outcomes with device use were noted.

Для цитирования: Tan Nicholas, Fei Gao, Rizwan Amanullah Mohammed, Lim Soo Teik, Abdul Aziz Zameer, Govindasamy Sivaraj, Chao Victor Tar Toong, Ewe See Hooi, Ho Kay Woon, Yap Jonathan. Safety and efficacy of cerebral embolic protection in transcatheter aortic valve implantation: an updated meta-analysis.. AsiaIntervention. 2024. DOI: 10.4244/aij-d-23-00022.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.