Range of Normal and Abnormal Syndesmotic Measurements Using Weightbearing CT.

Hagemeijer Noortje Catharina, Chang Song Ho, Abdelaziz Mohamed Elghazy, Casey Jack Christopher, Waryasz Gregory Richard, Guss Daniel, DiGiovanni Christopher William

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Early recognition of syndesmotic instability is critical for optimizing clinical outcome. Injuries causing a more subtle instability, however, can be difficult to diagnose. The purpose of this study was to evaluate both distal tibiofibular articulations using weightbearing computed tomography (CT) in patients with known syndesmotic instability, thereafter comparing findings between the injured and uninjured sides. We also aimed to define the range of normal measurement variation among patients without syndesmotic injury.

METHODS

Patients with unilateral syndesmotic instability requiring operative fixation (n = 12) underwent preoperative bilateral ankle weightbearing CT. A separate cohort of patients without ankle injury who also underwent bilateral ankle weightbearing CT were included as comparative controls (n = 24). For each weightbearing CT, a series of 7 axial plane tibiofibular joint measurements, including 1 angular measurement, were utilized to evaluate parameters of the syndesmotic anatomy at a level 1 cm above the tibial plafond. Values were recorded by 2 independent observers to assess for interobserver reliability.

RESULTS

Among those with unilateral syndesmotic instability, values differed between the injured and uninjured sides in 4 of the 7 measurements performed including the syndesmotic area: direct anterior, middle, and posterior differences, and sagittal translation (P < .001, < .001, < .001, and < .001, respectively). In the control population without ankle injury, no differences were identified between any of the bilateral measurements (P value range, .172-.961).

CONCLUSION

This study highlights the ability of weightbearing CT to effectively differentiate syndesmotic diastasis among patients with surgically confirmed syndesmotic instability from those without syndesmotic instability. It underscores the substantial utility and importance of using the contralateral, uninjured side as a valid internal control whenever the need for confirming potential syndesmotic instability arises. Prospective studies are necessary to fully understand the accuracy of weightbearing CT in diagnosing occult syndesmotic instability among patients for whom the diagnosis remains in question.

LEVEL OF EVIDENCE: Level III, comparative diagnostic study.

Для цитирования: Hagemeijer Noortje Catharina, Chang Song Ho, Abdelaziz Mohamed Elghazy, Casey Jack Christopher, Waryasz Gregory Richard, Guss Daniel, DiGiovanni Christopher William. Range of Normal and Abnormal Syndesmotic Measurements Using Weightbearing CT.. Foot & ankle international. 2019. DOI: 10.1177/1071100719866831.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.