MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2217/nnm.12.125

Медицинская библиотека · Nanomedicine (London, England) · 2012

Functional interaction between charged nanoparticles and cardiac tissue: a new paradigm for cardiac arrhythmia?

Miragoli Michele, Novak Pavel, Ruenraroengsak Pakatip, Shevchuk Andrew I, Korchev Yuri E, Lab Max J, Tetley Teresa D, Gorelik Julia

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIM: To investigate the effect of surface charge of therapeutic nanoparticles on sarcolemmal ionic homeostasis and the initiation of arrhythmias.

MATERIALS &

METHODS

Cultured neonatal rat myocytes were exposed to 50 nm-charged polystyrene latex nanoparticles and examined using a combination of hopping probe scanning ion conductance microscopy, optical recording of action potential characteristics and patch clamp.

RESULTS

Positively charged, amine-modified polystyrene latex nanoparticles showed cytotoxic effects and induced large-scale damage to cardiomyocyte membranes leading to calcium alternans and cell death. By contrast, negatively charged, carboxyl-modified polystyrene latex nanoparticles (NegNPs) were not overtly cytotoxic but triggered formation of 50-250-nm nanopores in the membrane. Cells exposed to NegNPs revealed pro-arrhythmic events, such as delayed afterdepolarizations, reduction in conduction velocity and pathological increment of action potential duration together with an increase in ionic current throughout the membrane, carried by the nanopores.

CONCLUSION

The utilization of charged nanoparticles is a novel concept for targeting cardiac excitability. However, this unique nanoscopic investigation reveals an altered electrophysiological substrate, which sensitized the heart cells towards arrhythmias.

Для цитирования: Miragoli Michele, Novak Pavel, Ruenraroengsak Pakatip, Shevchuk Andrew I, Korchev Yuri E, Lab Max J, Tetley Teresa D, Gorelik Julia. Functional interaction between charged nanoparticles and cardiac tissue: a new paradigm for cardiac arrhythmia?. Nanomedicine (London, England). 2012. DOI: 10.2217/nnm.12.125.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.