Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year.

Wilcke Maria K T, Abbaszadegan Hassan, Adolphson Per Y

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Promising results have been reported after volar locked plating of unstable dorsally displaced distal radius fractures. We investigated whether volar locked plating results in better patient-perceived, objective functional and radiographic outcomes compared to the less invasive external fixation.

PATIENTS AND

METHODS

63 patients under 70 years of age, with an unstable extra-articular or non-comminuted intra-articular dorsally displaced distal radius fracture, were randomized to volar locked plating (n = 33) or bridging external fixation. Patient-perceived outcome was assessed with the Disability of the Arm, Shoulder, and Hand (DASH) questionnaire and the Patient-Rated Wrist Evaluation (PRWE) questionnaire.

RESULTS

At 3 and 6 months, the volar plate group had better DASH and PRWE scores but at 12 months the scores were similar. Objective function, measured as grip strength and range of movement, was superior in the volar plate group but the differences diminished and were small at 12 months. Axial length and volar tilt were retained slightly better in the volar plate group.

INTERPRETATION: Volar plate fixation is more advantageous than external fixation, in the early rehabilitation period.

Для цитирования: Wilcke Maria K T, Abbaszadegan Hassan, Adolphson Per Y. Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year.. Acta orthopaedica. 2011. DOI: 10.3109/17453674.2011.552781.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.