MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/07853890.2024.2304664

Медицинская библиотека · Annals of medicine · 2024

Validity and reliability of automated treadmill six-minute walk test in patients entering exercise-based cardiac rehabilitation.

Nevelikova Marketa, Dosbaba Filip, Pepera Garyfallia, Felsoci Marian, Batalikova Katerina, Su Jing Jing, Batalik Ladislav

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Introduction

The six-minute walk test (6MWT) is a well-established tool for assessing submaximal functional capacity for cardiac patients, but space limitations challenge its implementation. Treadmill-based (TR) 6MWT is a promising alternative, but it requires patients to complete a familiarization test to adapt treadmill speed regulation. With the advancement of sensors, it is possible to automatically control speed for individual patients and thus overcome the space limitation or the speed control difficulty on the treadmill for each patient.

Methods

This study investigated the validity and interchangeability of automated speed TR6MWT and standard hallway (HL) 6MWT. Eighteen patients were assessed at baseline of the 12-week cardiac rehabilitation program. Fourteen of them were assessed after rehabilitation. All patients performed three TR6MWTs and three HL6MWTs at baseline and one of each test after the program.

Results

Patients well tolerated the TR6MWT. There was a strong correlation between both test methods (r = 0.79). However, patients performed significantly better in HL6MWT (514.8m ± 59.7m) than in TR6MWT (447.2 ± 79.1m) with 95% CI, 40.4-94.6m, p < 0.05. Both tests showed high test-retest reliability (intraclass correlation coefficient of 0.86). The TR6MWT showed a valuable comparison of the effect of the cardiac rehabilitation program (20% increase, effect size 1.1) even though it is not interchangeable with the HL6MWT.

Conclusion

The automated speed TR6MWT appears to be an acceptable tool with adequate validity, reliability, and responsiveness for assessing functional capacity in patients utilizing cardiac rehabilitation programs.

Для цитирования: Nevelikova Marketa, Dosbaba Filip, Pepera Garyfallia, Felsoci Marian, Batalikova Katerina, Su Jing Jing, Batalik Ladislav. Validity and reliability of automated treadmill six-minute walk test in patients entering exercise-based cardiac rehabilitation.. Annals of medicine. 2024. DOI: 10.1080/07853890.2024.2304664.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.