Fa yi xue za zhi · 2011
[Simultaneous determination of trihexyphenidyl, chlorpromazine and clozapine in blood by GC-MS].
Аннотация на английскомСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zheng Shui-Qing, Wang Wei, Liang Chen, Wang Rong, Gong Fei-Jun, Wu Zhong-Ping, Chen Yong-Sheng, Zhang Yu-Rong, Zhang Run-Sheng
Аннотация
OBJECTIVE: To develop a method to measure trihexyphenidyl, chlorpromazine and clozapine in human blood with GC-MS.
METHODS: The specimens were alkalized (pH > 10) and extracted with V (benzene):V(ethyl acetate) = 1:1, and qualitatively analyzed using GC-MS-Full Scan with internal standard SKF525A. The specimens were alkalized (pH > 10) and extracted with V(benzene):V(ethyl acetate) = 1:1, and quantitatively analyzed using GC-MS-SIM with internal standard diazepam-d5.
RESULTS: The lowest detection limits of trihexyphenidyl, chlorpromazine and clozapine were 0.3, 0.3 and 0.7 ng/mL (S/N > or = 3) respectively. The calibration curve in 20-10 000 ng/mL showed a good linear distribution. The recovery rate was 79.9% to 85.5%. The RSDs of intraday and interday were less than 5.1%.
CONCLUSION: The established method was simple, sensitive and accurate for simultaneous determination of trihexyphenidyl, chlorpromazine and clozapine in human blood, and can be applied in forensic toxicological cases.
METHODS: The specimens were alkalized (pH > 10) and extracted with V (benzene):V(ethyl acetate) = 1:1, and qualitatively analyzed using GC-MS-Full Scan with internal standard SKF525A. The specimens were alkalized (pH > 10) and extracted with V(benzene):V(ethyl acetate) = 1:1, and quantitatively analyzed using GC-MS-SIM with internal standard diazepam-d5.
RESULTS: The lowest detection limits of trihexyphenidyl, chlorpromazine and clozapine were 0.3, 0.3 and 0.7 ng/mL (S/N > or = 3) respectively. The calibration curve in 20-10 000 ng/mL showed a good linear distribution. The recovery rate was 79.9% to 85.5%. The RSDs of intraday and interday were less than 5.1%.
CONCLUSION: The established method was simple, sensitive and accurate for simultaneous determination of trihexyphenidyl, chlorpromazine and clozapine in human blood, and can be applied in forensic toxicological cases.