Home sleep apnea testing of adults with chronic heart failure.

Li Shengnan, Xu Liyue, Dong Xiaosong, Zhang Xueli, Keenan Brendan T, Han Fang, Bi Taoran, Chang Yuan, Yu Yongbo, Zhou Bing, Pack Allan I, Kuna Samuel T

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

OBJECTIVES

To evaluate home sleep apnea testing (HSAT) using a type 3 portable monitor to help diagnose sleep-disordered breathing (SDB) and identify respiratory events including obstructive sleep apnea, central sleep apnea, and Cheyne-Stokes respiration in adults with stable chronic heart failure.

METHODS

Eighty-four adults with chronic heart failure (86.9% males, age [mean ± standard deviation] 58.7 ± 16.3 years, body mass index 29.4 ± 13.0 kg/m², left ventricular ejection fraction 40.3% ± 11.5%) performed unattended HSAT followed by an in-laboratory polysomnography (PSG) with simultaneous portable monitor recording.

RESULTS

The apnea-hypopnea index was 22.0 ± 17.0 events/h according to HSAT, 26.8 ± 20.5 events/h on an in-laboratory portable monitor, and 23.8 ± 21.3 events/h using PSG (P = .373). A Bland-Altman analysis of the apnea-hypopnea index using HSAT vs PSG showed a mean difference (95% confidence interval) of -2.4 (-4.9 to 0.1) events/h and limits of agreement (±2 standard deviations) of -24.1 to 19.2 events/h. HSAT underestimated the apnea-hypopnea index to a greater extent at a higher apnea-hypopnea index (rho = -.358; P < .001). Similar levels of agreement from HSAT vs PSG were observed when comparing the obstructive apnea index, central apnea index, and percentage of time in a Cheyne-Stokes respiration pattern. When we used an apnea-hypopnea index ≥ 5 events/h to diagnose SDB, HSAT had 86.7% sensitivity, 76.5% specificity, 92.9% positive predictive value, and 61.9% negative predictive value compared to PSG. Detection of Cheyne-Stokes respiration using HSAT showed 94.6% sensitivity, 91.1% specificity, 88.6% positive predictive value, and 97.6% negative predictive value compared to PSG.

CONCLUSIONS

HSAT with a type 3 portable monitor can help diagnose SDB and identify obstructive sleep apnea, central sleep apnea, and Cheyne-Stokes respiration events in adults with chronic heart failure.

Для цитирования: Li Shengnan, Xu Liyue, Dong Xiaosong, Zhang Xueli, Keenan Brendan T, Han Fang, Bi Taoran, Chang Yuan, Yu Yongbo, Zhou Bing, Pack Allan I, Kuna Samuel T. Home sleep apnea testing of adults with chronic heart failure.. Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine. 2021. DOI: 10.5664/jcsm.9224.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.