MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41551-021-00802-0

Медицинская библиотека · Nature biomedical engineering · 2021

Wirelessly operated bioelectronic sutures for the monitoring of deep surgical wounds.

Kalidasan Viveka, Yang Xin, Xiong Ze, Li Renee R, Yao Haicheng, Godaba Hareesh, Obuobi Sybil, Singh Priti, Guan Xin, Tian Xi, Kurt Selman A, Li Zhipeng, Mukherjee Devika, Rajarethinam Ravisankar, Chong Choon Seng, Wang Jiong-Wei, Ee Pui Lai Rachel, Loke Weiqiang, Tee Benjamin C K, Ouyang Jianyong, Charles Christopher J, Ho John S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Monitoring surgical wounds post-operatively is necessary to prevent infection, dehiscence and other complications. However, the monitoring of deep surgical sites is typically limited to indirect observations or to costly radiological investigations that often fail to detect complications before they become severe. Bioelectronic sensors could provide accurate and continuous monitoring from within the body, but the form factors of existing devices are not amenable to integration with sensitive wound tissues and to wireless data transmission. Here we show that multifilament surgical sutures functionalized with a conductive polymer and incorporating pledgets with capacitive sensors operated via radiofrequency identification can be used to monitor physicochemical states of deep surgical sites. We show in live pigs that the sutures can monitor wound integrity, gastric leakage and tissue micromotions, and in rodents that the healing outcomes are equivalent to those of medical-grade sutures. Battery-free wirelessly operated bioelectronic sutures may facilitate post-surgical monitoring in a wide range of interventions.

Для цитирования: Kalidasan Viveka, Yang Xin, Xiong Ze, Li Renee R, Yao Haicheng, Godaba Hareesh, Obuobi Sybil, Singh Priti, Guan Xin, Tian Xi, Kurt Selman A, Li Zhipeng, Mukherjee Devika, Rajarethinam Ravisankar, Chong Choon Seng, Wang Jiong-Wei, Ee Pui Lai Rachel, Loke Weiqiang, Tee Benjamin C K, Ouyang Jianyong, Charles Christopher J, Ho John S. Wirelessly operated bioelectronic sutures for the monitoring of deep surgical wounds.. Nature biomedical engineering. 2021. DOI: 10.1038/s41551-021-00802-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.