MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Journal of reproductive medicine · 1999

Accuracy of sonographically estimated fetal weight with and without oligohydramnios. A case-control study.

Chauhan S P, Scardo J A, Hendrix N W, Magann E F, Morrison J C

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine the accuracy of sonographically estimated fetal weight among women with and without oligohydramnios (amniotic fluid index [AFI] < or = 5.0 cm) and to ascertain the ability to detect fetal growth restriction (FGR) (estimated birth weight < 10th percentile for gestational age [GA]) among patients in two groups.

STUDY

DESIGN

Assuming that 50% of sonographic predictions are within 10% of the birth weight in the study group, 300 parturients are necessary to show a difference of 15% among controls (alpha = .05, beta = .02). The study group consisted of parturients with a reliable GA of > or = 24, no known anomalies and known AFI of < or = 5.0 cm. The control (1:1) was the next patient with the same GA but AFI between 5.1 and 23.9 cm. The paired t test was used, and the odds ratio (OR) and 95% confidence interval (CI) were calculated. P < .05 was considered significant.

RESULTS

Among the study and control groups (N = 162 each), maternal demographics, mean estimate (P = .078) and actual birth weight (P = .091) were similar. Sonographic estimates within 10% of weight were not significantly different among those with (57%) and without oligohydramnios (59%; OR 0.92; 95% CI 0.59, 1.44). The frequency of FGR was higher among those with inadequate fluid (18%) than controls (9%; OR 2.13; 95% CI 1.10, 4.16). Sensitivity, positive predictive value and likelihood ratio were higher among those with oligohydramnios (76%, 78% and 16) than controls (53%, 42% and 7).

CONCLUSION

The accuracy of sonographic estimates of fetal weight is not influenced by whether the parturient has oligohydramnios. Moreover, the accuracy of identifying FGR is not diminished among those with AFI < or = 5.0 versus > 5.0 cm.

Для цитирования: Chauhan S P, Scardo J A, Hendrix N W, Magann E F, Morrison J C. Accuracy of sonographically estimated fetal weight with and without oligohydramnios. A case-control study.. The Journal of reproductive medicine. 1999.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.