MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.colsurfb.2022.112984

Медицинская библиотека · Colloids and surfaces. B, Biointerfaces · 2022

Sensitive Zika biomarker detection assisted by quantum dot-modified electrochemical immunosensing platform.

Ribeiro Jéssika F F, Melo José R S, Santos Caroline de L, Chaves Claudilene R, Cabral Filho Paulo E, Pereira Goreti, Santos Beate S, Pereira Giovannia A L, Rosa Daniela S, Ribeiro Rogério T, Fontes Adriana

СтатьяПеревод в очереди

Аннотация

We report the development of a new nanostructured electrochemical immunosensing platform for the detection of the Zika virus envelope protein (EP-ZIKV). For this, quantum dots (QDs) were explored in combination with screen-printed carbon electrodes (SPCEs) functionalized with a conductor polymeric film, formed from 2-(1H-pyrrol-1-yl)ethanamine (Pyam), and anti-EP DIII ZIKV antibodies. Carboxylated CdTe QDs were synthesized, characterized by optical and structural techniques, and covalently immobilized onto the SPCE/PPyam surface. Then, anti-EP ZIKV antibodies were also covalently conjugated to QDs. All stages of platform assembly were evaluated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The detection of EP-ZIKV was performed by differential pulse voltammetry (DPV). Results indicated that QDs were efficiently immobilized, and did not show oxidation, under the conditions evaluated, for at least 7 months. Anti-EP ZIKV antibodies were effectively immobilized on the PPyam/QDs surface, even after 2 months of electrode storage. The platform enabled the detection of EP-ZIKV with high sensitivity using minimal sample volumes (LOD = 0.1 ng mL-1 and LOQ = 0.4 ng mL-1). The platform was also able to detect EP-ZIKV in spiked serum samples. Moreover, the platform showed specificity, not detecting the EP-DENV 3 nor a mixture of four DENV serotypes antigens. Thus, the proposed combination favored the development of a sensitive immunosensing platform, promising for the detection of Zika in the viremic phase, which also holds potential for transposition to other arboviruses.

Для цитирования: Ribeiro Jéssika F F, Melo José R S, Santos Caroline de L, Chaves Claudilene R, Cabral Filho Paulo E, Pereira Goreti, Santos Beate S, Pereira Giovannia A L, Rosa Daniela S, Ribeiro Rogério T, Fontes Adriana. Sensitive Zika biomarker detection assisted by quantum dot-modified electrochemical immunosensing platform.. Colloids and surfaces. B, Biointerfaces. 2022. DOI: 10.1016/j.colsurfb.2022.112984.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.