MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejvsvf.2023.05.001

Медицинская библиотека · EJVES vascular forum · 2023

Automatic Detection of Visceral Arterial Aneurysms on Computed Tomography Angiography Using Artificial Intelligence Based Segmentation of the Vascular System.

Lareyre Fabien, Caradu Caroline, Chaudhuri Arindam, Lê Cong Duy, Di Lorenzo Gilles, Adam Cédric, Carrier Marion, Raffort Juliette, Study Group Collaborators

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Visceral arterial aneurysms (VAAs) are life threatening. Due to the paucity of symptoms and rarity of the disease, VAAs are underdiagnosed and underestimated. Artificial intelligence (AI) offers new insights into segmentation of the vascular system, and opportunities to better detect VAAs. This pilot study aimed to develop an AI based method to automatically detect VAAs from computed tomography angiography (CTA).

METHODS

A hybrid method combining a feature based expert system with a supervised deep learning algorithm (convolutional neural network) was used to enable fully automatic segmentation of the abdominal vascular tree. Centrelines were built and reference diameters of each visceral artery were calculated. An abnormal dilatation (VAAs) was defined as a substantial increase in diameter at the pixel of interest compared with the mean diameter of the reference portion. The automatic software provided 3D rendered images with a flag on the identified VAA areas. The performance of the method was tested in a dataset of 33 CTA scans and compared with the ground truth provided by two human experts.

RESULTS

Forty-three VAAs were identified by human experts (32 in the coeliac trunk branches, eight in the superior mesenteric artery, one in the left renal, and two in the right renal arteries). The automatic system accurately detected 40 of the 43 VAAs, with a sensitivity of 0.93 and a positive predictive value of 0.51. The mean number of flag areas per CTA was 3.5 ± 1.5 and they could be reviewed and checked by a human expert in less than 30 seconds per CTA.

CONCLUSION

Although the specificity needs to be improved, this study demonstrates the potential of an AI based automatic method to develop new tools to improve screening and detection of VAAs by automatically attracting clinicians' attention to suspicious dilatations of the visceral arteries.

Для цитирования: Lareyre Fabien, Caradu Caroline, Chaudhuri Arindam, Lê Cong Duy, Di Lorenzo Gilles, Adam Cédric, Carrier Marion, Raffort Juliette, Study Group Collaborators. Automatic Detection of Visceral Arterial Aneurysms on Computed Tomography Angiography Using Artificial Intelligence Based Segmentation of the Vascular System.. EJVES vascular forum. 2023. DOI: 10.1016/j.ejvsvf.2023.05.001.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.