MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0305296

Медицинская библиотека · PloS one · 2024

Data quality assessment of the Enhanced Gonococcal Antimicrobial Surveillance Programme (EGASP), Thailand, 2015-2021.

Tongtoyai Jaray, Cherdtrakulkiat Thitima, Girdthep Natnaree, Masciotra Silvina, Winaitham Santi, Sangprasert Pongsathorn, Daengsaard Ekkachai, Puangsoi Anuparp, Kittiyaowamarn Rossaphorn, Dunne Eileen F, Sirivongrangson Pachara, Hickey Andrew C, Weston Emily, Frankson Rebekah M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Quality assessments of gonococcal surveillance data are critical to improve data validity and to enhance the value of surveillance findings. Detecting data errors by systematic audits identifies areas for quality improvement. We designed and implemented an internal audit process to evaluate the accuracy and completeness of surveillance data for the Thailand Enhanced Gonococcal Antimicrobial Surveillance Programme (EGASP).

METHODS

We conducted a data quality audit of source records by comparison with the data stored in the EGASP database for five audit cycles from 2015-2021. Ten percent of culture-confirmed cases of Neisseria gonorrhoeae were randomly sampled along with any cases identified with elevated antimicrobial susceptibility testing results and cases with repeat infections. Incorrect and incomplete data were investigated, and corrective action and preventive actions (CAPA) were implemented. Accuracy was defined as the percentage of identical data in both the source records and the database. Completeness was defined as the percentage of non-missing data from either the source document or the database. Statistical analyses were performed using the t-test and the Fisher's exact test.

RESULTS

We sampled and reviewed 70, 162, 85, 68, and 46 EGASP records during the five audit cycles. Overall accuracy and completeness in the five audit cycles ranged from 93.6% to 99.4% and 95.0% to 99.9%, respectively. Overall, completeness was significantly higher than accuracy (p = 0.017). For each laboratory and clinical data element, concordance was >85% in all audit cycles except for two laboratory data elements in two audit cycles. These elements significantly improved following identification and CAPA implementation.

DISCUSSION: We found a high level of data accuracy and completeness in the five audit cycles. The implementation of the audit process identified areas for improvement. Systematic quality assessments of laboratory and clinical data ensure high quality EGASP surveillance data to monitor for antimicrobial resistant Neisseria gonorrhoeae in Thailand.

Для цитирования: Tongtoyai Jaray, Cherdtrakulkiat Thitima, Girdthep Natnaree, Masciotra Silvina, Winaitham Santi, Sangprasert Pongsathorn, Daengsaard Ekkachai, Puangsoi Anuparp, Kittiyaowamarn Rossaphorn, Dunne Eileen F, Sirivongrangson Pachara, Hickey Andrew C, Weston Emily, Frankson Rebekah M. Data quality assessment of the Enhanced Gonococcal Antimicrobial Surveillance Programme (EGASP), Thailand, 2015-2021.. PloS one. 2024. DOI: 10.1371/journal.pone.0305296.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.