MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2009.06.126

Медицинская библиотека · The Annals of thoracic surgery · 2010

Cardiac function assessed by transesophageal echocardiography during pectus excavatum repair.

Krueger Thorsten, Chassot Pierre-Guy, Christodoulou Michel, Cheng Cai, Ris Hans-Beat, Magnusson Lennart

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

We assessed end-diastolic right ventricular (RV) dimensions and left ventricular (LV) ejection fraction by use of intraoperative transesophageal echocardiography before and after surgical correction of pectus excavatum in adults.

METHODS

A prospective study was conducted including 17 patients undergoing surgical correction of pectus excavatum according to the technique of Ravitch-Shamberger between 1999 and 2004. Intraoperative transesophageal echocardiography was performed under general anesthesia before and after surgery to assess end-diastolic RV dimensions and LV ejection fraction. The end-diastolic RV diameter and area were measured in four-chamber and RV inflow-outflow view, and the RV volume was calculated from these data. The LV was assessed by transgastric short-axis view, and its ejection fraction was calculated by use of the Teichholz formula.

RESULTS

The end-diastolic RV diameter, area, and volume all significantly increased after surgery (mean values +/- SD, respectively: 2.4 +/- 0.8 cm versus 3.0 +/- 0.9 cm, p < 0.001; 12.5 +/- 5.2 cm(2) versus 18.4 +/- 7.5 cm(2), p < 0.001; and 21.7 +/- 11.7 mL versus 40.8 +/- 23 mL, p < 0.001). The LV ejection fraction also significantly increased after surgery (58.4% +/- 15% versus 66.2% +/- 6%, p < 0.001).

CONCLUSIONS

Surgical correction of pectus excavatum according to Ravitch-Shamberger technique results in a significant increase in end-diastolic RV dimensions and a significantly increased LV ejection fraction.

Для цитирования: Krueger Thorsten, Chassot Pierre-Guy, Christodoulou Michel, Cheng Cai, Ris Hans-Beat, Magnusson Lennart. Cardiac function assessed by transesophageal echocardiography during pectus excavatum repair.. The Annals of thoracic surgery. 2010. DOI: 10.1016/j.athoracsur.2009.06.126.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.