MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/sdi.12249

Медицинская библиотека · Seminars in dialysis · 2014

Cardiovascular implantable electronic devices in hemodialysis patients: prevalence and implications for arteriovenous hemodialysis access interventions.

Saad Theodore F, Ahmed Waqas, Davis Karen, Jurkovitz Claudine

СтатьяПеревод в очереди

Аннотация

Cardiovascular implantable electronic devices (CIEDs) are frequently utilized in hemodialysis patients. CIED leads are typically implanted via the subclavian vein resulting in stenosis and venous hypertension. We studied 1235 chronic hemodialysis patients under the care of our nephrology practice. For each, we determined the presence of a CIED, indication for implantable cardioverter-defibrillator (ICD), and type of hemodialysis access. Records were reviewed to identify all interventions performed on the access circuit and the central veins specifically. A CIED was present in 129 patients (10.5%), including ICDs in 75 (6.1%) and pacemakers in 54 (4.4%). The access circuit intervention rate was 1.48/access year (AY) and was similar when a CIED was ipsilateral (1.53/AY) or contralateral (1.44/AY) to arteriovenous access (p = 0.477). The rate of central venous interventions was greater in the ipsilateral (0.59/AY) versus contralateral group (0.28/AY), (p < 0.001). Fifty-four of 59 patients with ipsilateral access and CIED required <2 interventions per AY, but six failed angioplasty and required access ligation. None had superior vena cava stenosis requiring intervention. We conclude that there is a high prevalence of CIEDs in our HD patients. Ipsilateral CIED and arteriovenous access results in higher central venous intervention rates compared with contralateral cases; overall access circuit intervention rates are similar.

Для цитирования: Saad Theodore F, Ahmed Waqas, Davis Karen, Jurkovitz Claudine. Cardiovascular implantable electronic devices in hemodialysis patients: prevalence and implications for arteriovenous hemodialysis access interventions.. Seminars in dialysis. 2014. DOI: 10.1111/sdi.12249.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.