Acute myocardial infarction: contrast-enhanced multi-detector row CT in a porcine model.

Hoffmann Udo, Millea Ryan, Enzweiler Christian, Ferencik Maros, Gulick Scott, Titus Jim, Achenbach Stephan, Kwait Dylan, Sosnovik David, Brady Thomas J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To assess the role of contrast material-enhanced retrospectively electrocardiographically (ECG) gated multi-detector row computed tomography (CT) in the detection of acute myocardial infarction in a porcine model of total coronary occlusion.

MATERIALS AND

METHODS

Seven Yorkshire farm pigs were studied with contrast-enhanced retrospectively ECG-gated multi-detector row CT 3 hours after total occlusion of the distal left anterior descending artery (n = 5) or the second diagonal branch (n = 2). Reformatted short-axis end-systolic and end-diastolic CT data sets were assessed for myocardial perfusion deficits, coronary occlusion, and abnormal myocardial wall motion. Perfusion deficits were compared with microsphere-determined blood flow and triphenyltetrazolium chloride (TTC)-stained tissue samples for infarct assessment by using Bland-Altman analysis and analysis of variance.

RESULTS

Myocardial perfusion deficits, occlusion of the left anterior descending artery or second diagonal branch, and akinesis of the infarcted segment were identified in all five animals that completed the study. One animal died, and one data set had nondiagnostic image quality. The CT end-diastolic (mean, 16.1% +/- 4.8 [SD]; range, 8.6%-22.2%) and end-systolic (mean, 17.0% +/- 6.4; range, 8.7%-26.8%) volume of perfusion deficit was similar to that of infarcted tissue at TTC staining (mean, 13.6% +/- 6.0; range, 7.8%-30.9%). Infarcted myocardium at CT demonstrated a 76.1% reduction in microsphere-determined blood flow and a significant reduction of myocardial CT attenuation compared with normal myocardium (P <.01). Myocardial wall motion analysis demonstrated absence of systolic wall thickening in infarcted myocardium.

CONCLUSION

Multi-detector row CT with retrospective ECG gating permits the detection and further characterization of acute myocardial infarction in a porcine model of complete coronary occlusion.

Для цитирования: Hoffmann Udo, Millea Ryan, Enzweiler Christian, Ferencik Maros, Gulick Scott, Titus Jim, Achenbach Stephan, Kwait Dylan, Sosnovik David, Brady Thomas J. Acute myocardial infarction: contrast-enhanced multi-detector row CT in a porcine model.. Radiology. 2004. DOI: 10.1148/radiol.2313030132.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.