MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5301/hip.2012.9209

Медицинская библиотека · Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2012

Minimum 5-year follow-up after Cormet hip resurfacing. A single surgeon series of 234 hips.

Kordás Geza, Baxter Jon, Parsons Nick, Costa Matthew L, Krikler Steve J

СтатьяПеревод в очереди

Аннотация

The performance of the Cormet hip resurfacing device was evaluated after a minimum of 5 years in 234 hips. The mean age of the patients was 54 years; there were 135 men and 80 women. The primary diagnosis was osteoarthritis in 78% of the patients. Outcome measures were the Harris Hip Score and implant survival. The overall survival rate was 94% with 12 revisions in women and 3 in men. There were 7 femoral and 5 acetabular failures and two revisions for groin pain. Cumulative survival rate in men and women was 98% and 89%, in patients with a femoral component larger than 44 mm and smaller than 44 mm 97% and 89% respectively. Patients with primary osteoarthritis had a 95% cumulative survival rate at 5 years. The risk of failure was 6.4 times higher in women than in men. Our results suggest that hip resurfacing with the Cormet device is an acceptable alternative for active patients with hip arthritis, but patient selection is crucial for good long-term results.

Для цитирования: Kordás Geza, Baxter Jon, Parsons Nick, Costa Matthew L, Krikler Steve J. Minimum 5-year follow-up after Cormet hip resurfacing. A single surgeon series of 234 hips.. Hip international : the journal of clinical and experimental research on hip pathology and therapy. 2012. DOI: 10.5301/hip.2012.9209.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.