Development of a Novel Fluorescent-Based Lateral Flow Assay for the Detection of Neisseria gonorrhoeae at the Point of Care.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gleeson Birgitta, Piton Jeremie, Mazzola Laura, McHugh Sean, Bender Jillian, Lear Madison, Gavrikova Tatyana, Van Der Pol Barbara, Daniels Brice, Osborn Jennifer, Dailey Peter, Ferreyra Cecilia

Аннотация

BACKGROUND: Neisseria gonorrhoeae (NG) has acquired significant resistance, primarily due to extensive and unwarranted antibiotic utilization over several decades. This resistance has largely been associated with the syndromic management of sexually transmitted infections, particularly in low- and middle-income countries where affordable point of care tests are unavailable. To address this diagnostic gap, FIND has developed a low-cost lateral flow assay for the detection of NG at the point of care.

METHODS: The early performance of the lateral flow assay was evaluated using frozen clinical samples. Limit of detection, inclusivity, and exclusivity studies were performed using well-characterized NG strains, common commensal genital microorganisms, and other Neisseria bacteria. Subsequently, clinical performance was evaluated at 2 sexual health clinics in Birmingham, Alabama.

RESULTS: The observed limit of detection with reference NG strains was 5 × 103 CFU/mL. Inclusivity was demonstrated for 31 NG strains. Exclusivity testing showed no cross-reactivity with 28 non-Neisseria and nongonococcal Neisseria species; cross-reactivity was observed with Neisseria meningitidis, Neisseria lactamica, and Neisseria polysaccharea. The lateral flow assay demonstrated clinical sensitivity and specificity of 78.6% and 100% in female vaginal swabs and 100% and 89.7% in male urine, respectively.

CONCLUSIONS: FIND has developed a lateral flow assay that aligns with the majority of the World Health Organization Target Product Profile criteria for confirming or excluding NG infection at the point of care. The NG lateral flow assay has now achieved design freeze (final device optimization) and is ready for technology transfer to a manufacturing partner. This test has the potential to support the shift in patient management from a syndromic to an etiological approach.