MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s44161-025-00677-3

Медицинская библиотека · Nature cardiovascular research · 2025

Mechanosensitive PIEZO2 channels shape coronary artery development.

Pampols-Perez Mireia, Fürst Carina, Sánchez-Carranza Oscar, Cano Elena, Garcia-Contreras Jonathan Alexis, Mais Lisa, Luo Wenhan, Raimundo Sandra, Lindberg Eric L, Taube Martin, Heuser Arnd, Sporbert Anje, Kainmueller Dagmar, Bernabeu Miguel O, Hübner Norbert, Gerhardt Holger, Lewin Gary R, Hammes Annette

СтатьяПеревод в очереди

Аннотация

Coronary arteries develop under constant mechanical stress. However, the role of mechanosensitive ion channels in this process remains poorly understood. Here we show that the ion channel PIEZO2, which responds to mechanical stimuli, is expressed in specific coronary endothelial cell populations during a critical phase of coronary vasculature remodeling. These Piezo2+ coronary endothelial cells show distinct transcriptional profiles and have mechanically activated ionic currents. Strikingly, PIEZO2 loss-of-function mouse embryos and mice with human pathogenic variants of PIEZO2 show abnormal coronary vessel development and cardiac left ventricular hyperplasia. We conclude that an optimal balance of PIEZO2 channel function contributes to proper coronary vessel formation, structural integrity and remodeling, and is likely to support normal cardiac function. Our study highlights the importance of mechanical cues in cardiovascular development and suggests that defects in this mechanosensing pathway may contribute to congenital heart conditions.

Для цитирования: Pampols-Perez Mireia, Fürst Carina, Sánchez-Carranza Oscar, Cano Elena, Garcia-Contreras Jonathan Alexis, Mais Lisa, Luo Wenhan, Raimundo Sandra, Lindberg Eric L, Taube Martin, Heuser Arnd, Sporbert Anje, Kainmueller Dagmar, Bernabeu Miguel O, Hübner Norbert, Gerhardt Holger, Lewin Gary R, Hammes Annette. Mechanosensitive PIEZO2 channels shape coronary artery development.. Nature cardiovascular research. 2025. DOI: 10.1038/s44161-025-00677-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.