MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7863/ultra.16.04023

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2017

Placental Characteristics of Fetuses With Congenital Heart Disease.

Albalawi Afaf, Brancusi Flavia, Askin Frederic, Ehsanipoor Robert, Wang Jiangxia, Burd Irina, Sekar Priya

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To investigate whether there is an association between congenital heart disease (CHD) and placental abnormalities.

METHODS

We conducted a case-control study that included cases of infants with CHD who underwent cardiac surgery within 6 months of life at the Johns Hopkins Medical Center from 2000 to 2013, and gestational age-matched normal pregnancy controls (200 neonates per group).

RESULTS

Overall, abnormal placental cord insertion (ie, eccentric, marginal, or velamentous) was associated with CHD (odds ratio, 2.33-3.76). The main cardiac defects associated with abnormal cord insertion were conotruncal defects (relative risk, 3.08; 95% confidence interval [CI], 1.48-6.40; P = .003), left heart disease (relative risk, 2.40; 95% CI, 1.32-4.37; P = .004), and right heart disease (relative risk, 2.22; 95% CI, 1.21-4.07; P = .010). The Placenta-to-birth weight ratio was not associated with CHD. Intrauterine growth restriction was associated with CHD (odds ratio, 3.00; 95% CI, 1.41-6.39; P = .004).

CONCLUSIONS

Abnormal cord insertion, as well as intrauterine growth restriction, was determined to be correlated with the presence of CHD. On the basis of our results, we conclude that cord insertion should be evaluated at routine obstetric sonography, and further fetal heart evaluation is warranted if abnormal cord insertion is detected.

Для цитирования: Albalawi Afaf, Brancusi Flavia, Askin Frederic, Ehsanipoor Robert, Wang Jiangxia, Burd Irina, Sekar Priya. Placental Characteristics of Fetuses With Congenital Heart Disease.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2017. DOI: 10.7863/ultra.16.04023.