MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jbspin.2012.02.002

Медицинская библиотека · Joint bone spine · 2012

Reproducibility of radiographic hip measurements in adults.

Bouttier Ronan, Morvan Johanne, Mazieres Bernard, Rat Anne-Christine, Ziegler Liana Euller, Fardellone Patrice, Fautrel Bruno, Guillemin Francis, Pouchot Jacques, Roux Christian, Coste Joël, Saraux Alain

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Hip dysplasia may cause pain and premature hip osteoarthritis. Here, our objective was to assess the inter- and intraobserver reproducibility of radiographic hip parameter measurement in adults.

METHODS

We used anteroposterior pelvic radiographs and false-profile lateral hip radiographs from 30 individuals (60 hips) enrolled in a prevalence study of hip osteoarthritis. For each hip, two independent observers recorded five parameters twice, at an interval of 1 month. The five parameters were the vertical-center-edge angle (VCE), the anterior center-edge angle (vertical-center-anterior angle, VCA), the acetabular roof angle (HTE), the neck-shaft angle (CC'D), and acetabulum depth (AD). Reproducibility was assessed using Bland-Altman plots, intraclass correlation coefficients (ICCs), and kappa coefficients for the radiographic diagnosis of hip dysplasia using widely accepted cutoffs.

RESULTS

Of the 60 hips, 51 were assessable. Intraobserver ICC values ranged from 0.72 to 0.94 and interobserver ICC values from 0.68 to 0.84. Kappa coefficients were between 0.60 and 1.00, except for the VCA angle (κ=0.41).

CONCLUSION

In this study, reproducibility of the main radiographic hip parameters was good according to all evaluation methods used. However, CC'D and, to an even greater extent, the VCA angle seemed challenging to measure.

Для цитирования: Bouttier Ronan, Morvan Johanne, Mazieres Bernard, Rat Anne-Christine, Ziegler Liana Euller, Fardellone Patrice, Fautrel Bruno, Guillemin Francis, Pouchot Jacques, Roux Christian, Coste Joël, Saraux Alain. Reproducibility of radiographic hip measurements in adults.. Joint bone spine. 2012. DOI: 10.1016/j.jbspin.2012.02.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.