DOI 10.1016/s1701-2163(15)30609-5
Do measurements of uterine septum using three-dimensional ultrasound and magnetic resonance imaging agree?
Аннотация
OBJECTIVE
To evaluate the agreement between measurements of uterine septum by 3-D ultrasound (3-D US) and magnetic resonance imaging.
METHODS
Fourteen women with a uterine septum underwent both a 3-D US and an MRI followed by hysteroscopic metroplasty in a tertiary care infertility clinic within a university teaching hospital. The agreement between 3-D US and MRI measurements of septum length (SL), septum width (SW) and the distance between fundal serosa and septal tip (SSD) was compared using the Bland Altman limit of agreement analysis.
RESULTS
3-D US correctly identified all women who had a uterine septum identified with MRI. The mean difference in SL was 2.7 mm (upper limit of agreement and lower limit of agreement were 10.3 mm and -4.8 mm, respectively). The mean difference in SW was 2.3 mm (upper limit of agreement and lower limit of agreement of 10.4 mm and -9.2 mm, respectively). The SSD mean difference was 2.8 mm (upper limit of agreement and lower limit of agreement of 10.6 mm and -5 mm, respectively).
CONCLUSIONS
Categorical agreement in diagnosis was 100% and agreement between 3-D US and MRI measurements was good with narrow differences. Variations were unlikely to be greater than intra- and inter-observer variations anticipated in MRI readings. 3-D US can replace MRI for diagnosis and measurement of uterine septa.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.