MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2471/blt.25.294507

Медицинская библиотека · Bulletin of the World Health Organization · 2026

Carbon emissions associated with antenatal testing for hepatitis B prophylaxis eligibility, the Gambia.

Ndiaye Alassane, Motyl Florian, Drammeh Sainabou, Dibba Bakary, Famiglietti Alexandra, Whittaker Maya, Jean Kévin, Lemoine Maud, Boyer Sylvie, Kania Dramane, Guingané Alice Nanelin, Hashimoto Naofumi, Tanaka Yasuhito, Sugiura Wataru, Murray Kris, Vandi Christopher, D'Alessandro Umberto, Guivel-Benhassine Florence, Da Conceicao Hélène, Pakula Guillaume, Ndow Gibril, Shimakawa Yusuke

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To estimate the carbon footprint of three diagnostic strategies to identify pregnant women eligible for antiviral prophylaxis to prevent hepatitis B vertical transmission in the Gambia.

METHODS

In 2024, we conducted a life cycle assessment of a point-of-care polymerase chain reaction (PCR) test using plasma, and a rapid diagnostic test for hepatitis B core-related antigen (HBcrAg) using plasma and capillary blood across three hospitals (rural, suburban and urban) and a suburban health centre. We included all products and processes in each diagnostic strategy. The functional unit was an antenatal testing episode assessing eligibility for antiviral prophylaxis, beginning after positive hepatitis B surface antigen screening. We estimated carbon emissions in grams of carbon dioxide equivalent (g CO2e) ± uncertainty.

FINDINGS: Mean carbon emissions per strategy were significantly different between point-of-care PCR and the rapid diagnostic tests (P-value: 0.028): 1619.0 ± 200.6 g CO2e (PCR), 520.4 ± 59.1 g CO2e (plasma-based rapid diagnostic test) and 374.3 ± 50.4 g CO2e (capillary-based test). Higher emissions with the PCR test were mainly driven by its reliance on air conditioning (759.1 g CO2e compared with 125.2 g CO2e for plasma-based rapid diagnostic test and 24.3 g CO2e for capillary-based test); the test itself (290.0 g CO2e versus 129.0 g CO2e for rapid diagnostic tests); and PCR-specific requirements including diagnostic device (47.0 g CO2e) and additional patient travel to collect results (255.8 g CO2e).

CONCLUSION

Our findings suggest that HBcrAg rapid diagnostic tests can reduce emissions substantially compared with point-of-care PCR. Our study demonstrates that life cycle assessments are feasible in resource-constrained settings and highlights the importance of integrating sustainability into hepatitis B diagnostic strategies.

Для цитирования: Ndiaye Alassane, Motyl Florian, Drammeh Sainabou, Dibba Bakary, Famiglietti Alexandra, Whittaker Maya, Jean Kévin, Lemoine Maud, Boyer Sylvie, Kania Dramane, Guingané Alice Nanelin, Hashimoto Naofumi, Tanaka Yasuhito, Sugiura Wataru, Murray Kris, Vandi Christopher, D'Alessandro Umberto, Guivel-Benhassine Florence, Da Conceicao Hélène, Pakula Guillaume, Ndow Gibril, Shimakawa Yusuke. Carbon emissions associated with antenatal testing for hepatitis B prophylaxis eligibility, the Gambia.. Bulletin of the World Health Organization. 2026. DOI: 10.2471/blt.25.294507.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.