MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s13239-011-0035-9

Медицинская библиотека · Cardiovascular engineering and technology · 2011

Effect of Geometry on the Leaflet Stresses in Simulated Models of Congenital Bicuspid Aortic Valves.

Jermihov Paul N, Jia Lu, Sacks Michael S, Gorman Robert C, Gorman Joseph H, Chandran Krishnan B

СтатьяПеревод в очереди

Аннотация

The aim of the study was to assess the effect of geometric variations on the stresses developed in the leaflets of congenital bicuspid aortic valves (CBAV). We developed a model for the human tri-leaflet aortic valve based on the geometry and dimensions published in the literature. We also developed simulated CBAV geometry based on the most common geometry present in patients with CBAV that is published in the literature. We employed a constitutive relationship for the leaflet material from the previously published experimental data of fresh porcine aortic valve leaflet specimens for the analysis. We performed dynamic finite element (FE) structural analysis of the valves in the aortic position in order to compute the strain and stress distribution on the leaflets of the tri-leaflet valve and the CBAV models. Our results showed that large changes in the computed in-plane leaflet strain and stress occurred with variations in the geometry of the simulated CBAV whereas changes due to alterations in material constants were correspondingly less. The valve orifice area in the fully open position was significantly reduced in CBAV compared to that for the tri-leaflet valve. The changes in geometry of CBAV resulted in large changes in in-plane strain and stress and our results suggest that geometrical variations may be a potential risk factor inducing calcific aortic stenosis frequently present in patients with CBAV.

Для цитирования: Jermihov Paul N, Jia Lu, Sacks Michael S, Gorman Robert C, Gorman Joseph H, Chandran Krishnan B. Effect of Geometry on the Leaflet Stresses in Simulated Models of Congenital Bicuspid Aortic Valves.. Cardiovascular engineering and technology. 2011. DOI: 10.1007/s13239-011-0035-9.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.