Adsorption of Blood Creatinine on a Heparin-Functionalized Surface of Copper-Based Metal-Organic Frameworks.
Аннотация
INTRODUCTION
Creatinine accumulation exacerbates outcomes in chronic kidney disease (CKD). To enhance creatinine removal and improve hemocompatibility, we developed heparin-functionalized copper-based metal-organic frameworks (CuMOFs-Hep).
METHODS
CuMOFs were heparinized via APTES bridging and characterized (XRD, SEM, FTIR, XPS, and zeta potential). Adsorption was evaluated in simulated CKD serum and was fitted with isotherm models. Whole-blood samples from patients/healthy donors were tested. Biosafety was assessed by Cu2+ leaching and platelet assays.
RESULTS
Heparinization increased surface negative charge and raised the maximum capacity to 267.8 mg g-1 (68.7% over pristine; Langmuir R 2 = 0.983). Adsorption kinetics studies indicate rapid clearance of creatinine, achieving a clearance rate of 65.9% within 30 min at 37°C and reaching 75.0% within 2 h. In patient blood (854.2 μmol/L), supernatant creatinine decreased to 163.2 μmol/L (80.9% removal). Cu2+ leaching dropped to 0.214 ppm (-89.9%), with reduced platelet adhesion/activation.
CONCLUSION
CuMOFs-Hep enables efficient, low-leaching creatinine adsorption in clinically relevant matrices, highlighting its promising potential as an efficient adsorbent for blood purification applications.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.