DOI 10.1038/s41598-023-40363-7
Feasibility and safety of non-contrast optical coherence tomography imaging using hydroxyethyl starch in coronary arteries.
Аннотация
Intracoronary optical coherence tomography (OCT) requires injection of flushing media for image acquisition. Alternative flushing media needs to be investigated to reduce the risk of contrast-induced renal dysfunction. We investigated the feasibility and safety of pentastarch (hydroxyethyl starch) for clinical OCT imaging. We prospectively enrolled 43 patients with 70 coronary lesions (46-stented; 24-native). Total 81 OCT pullback pairs were obtained by manual injection of iodine contrast, followed by pentastarch. Each pullback was assessed frame-by-frame using an automated customized lumen contour/stent strut segmentation algorithm. Paired images were compared for the clear image segments (CIS), blood-flushing capability, and quantitative morphometric measurements. Overall image quality, as assessed by the proportion of CIS, was comparable between the contrast- and pentastarch-flushed images (97.1% vs. 96.5%; p = 0.160). The pixel-based blood-flushing capability was similar between the groups (0.951 [0.947-0.953] vs. 0.950 [0.948-0.952], p = 0.125). Quantitative two- and three-dimensional morphometric measurements of the paired images correlated well (p < 0.001) with excellent inter-measurement variability. All patients safely underwent OCT imaging using pentastarch without resulting in clinically relevant complications or renal deterioration. Non-contrast OCT imaging using pentastarch is clinically safe and technically feasible with excellent image quality and could be a promising alternative strategy for patients at high risk of renal impairment.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.