DOI 10.1007/s00167-010-1227-9

Медицинская библиотека · Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2010

Intra-operative ultrasound facilitates the localization of the calcific deposit during arthroscopic treatment of calcifying tendinitis.

Sabeti-Aschraf M, Gonano C, Nemecek E, Cichocki L, Schueller-Weidekamm C

СтатьяПеревод в очереди

Аннотация

PURPOSE: Calcifying tendinitis is a common condition of the shoulder. In many cases, arthroscopic reduction in the deposit is indicated. The localization of the deposit is sometimes challenging and time-consuming. Pre-operative ultrasound (US)-guided needle placement in the deposit and pre-operative US marking of the deposit at the skin with a ballpoint are described and recommended methods to alleviate the procedure without using ionizing radiation by fluoroscopy.

METHODS

Intra-operative sonography of the shoulder is introduced as a new method to localize the calcific deposit with high accuracy. After standard arthroscopic buresectomy, the surgeon performs an ultrasound examination under sterile conditions to localize the deposits. A ventral longitudinal US section is recommended, and the upper arm is rotated until the deposit is visible. Subsequently, perpendicular to the skin at the position of the transducer, a needle is introduced under arthroscopic and ultrasound visualization to puncture the deposit.

RESULTS

The presence of snow-white crystals at the tip of the needle proves the exact localization. Consecutively, the curettage can be accomplished. Another intra-operative sonography evaluates possible calcific remnants and the tendon structure.

CONCLUSION

This new technique may alleviate arthroscopic calcific deposit curettage by visualizing the deposit without using ionizing radiation. Additionally, soft tissue damage due to decreased number of punctures to detect the deposit may be achieved. Both factors may contribute to reduced operation time.

Для цитирования: Sabeti-Aschraf M, Gonano C, Nemecek E, Cichocki L, Schueller-Weidekamm C. Intra-operative ultrasound facilitates the localization of the calcific deposit during arthroscopic treatment of calcifying tendinitis.. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 2010. DOI: 10.1007/s00167-010-1227-9.