MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arcped.2020.06.002

Медицинская библиотека · Archives de pediatrie : organe officiel de la Societe francaise de pediatrie · 2020

Comparison of three different noninvasive ventilation strategies as initial respiratory support in very low birth weight infants with respiratory distress syndrome: A retrospective study.

Buyuktiryaki M, Okur N, Sari F N, Ozer Bekmez B, Bezirganoglu H, Cakir U, Dizdar E A, Oguz S S

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

There is inadequate evidence regarding which noninvasive ventilation (NIV) is superior for initial respiratory support of preterm infants with respiratory distress syndrome.

OBJECTIVES

To compare the failure of noninvasive ventilation (NIV) and neonatal outcomes between nasal continuous positive airway pressure (NCPAP), bi-level positive airway pressure (BiPAP), and nasal intermittent positive pressure ventilation (NIPPV) as the initial respiratory support with less invasive surfactant administration (LISA) in very low birth weight (VLBW) infants.

METHODS

Medical records of 419 VLBW infants born at 26-30weeks' gestation who did not require intubation in the delivery room and were initially supported with either NCPAP (n=221), BiPAP (n=101), or NIPPV (n=97) were retrospectively reviewed. The LISA approach was preferred in cases of surfactant requirement. The primary outcome was the failure of NIV within the first 72h of life. Failure of NIV was defined as the persistence or recurrence of one or more of the following: hypoxemia, respiratory acidosis, more than one episode of apnea requiring bag and mask ventilation or more than six episodes of apnea requiring stimulation over a 6-h period. Data were analyzed using univariate and multivariate logistic regression analysis.

RESULTS

Failure of NIV within the first 72h of life was significantly higher in the NCPAP group (29.4%) compared with the BiPAP (12.9%) or NIPPV (12.4%) group (P<0.001). However, the BiPAP and NIPPV groups were not different in terms of NIV failure (P=0.91). Multivariable logistic regression analysis showed that antenatal steroid administration (OR: 0.49, 95% CI: 0.27-0.90; P=0.02) and gestational age˂28weeks (OR: 2.03, 95% CI: 1.18-3.49; P=0.01) were independent factors that influence failure of NIV within the first 72h of life.

CONCLUSION

Compared with NCPAP, the use of NIPPV/BiPAP strategies for initial respiratory support can reduce the need for invasive ventilation in infants born at 26-30weeks' gestation.

Для цитирования: Buyuktiryaki M, Okur N, Sari F N, Ozer Bekmez B, Bezirganoglu H, Cakir U, Dizdar E A, Oguz S S. Comparison of three different noninvasive ventilation strategies as initial respiratory support in very low birth weight infants with respiratory distress syndrome: A retrospective study.. Archives de pediatrie : organe officiel de la Societe francaise de pediatrie. 2020. DOI: 10.1016/j.arcped.2020.06.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.