MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-021-08323-9

Медицинская библиотека · European radiology · 2021

Diagnostic accuracy of quantitative dual-energy CT-based volumetric bone mineral density assessment for the prediction of osteoporosis-associated fractures.

Gruenewald Leon D, Koch Vitali, Martin Simon S, Yel Ibrahim, Eichler Katrin, Gruber-Rouh Tatjana, Lenga Lukas, Wichmann Julian L, Alizadeh Leona S, Albrecht Moritz H, Mader Christoph, Huizinga Nicole A, D'Angelo Tommaso, Mazziotti Silvio, Wesarg Stefan, Vogl Thomas J, Booz Christian

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the predictive value of volumetric bone mineral density (BMD) assessment of the lumbar spine derived from phantomless dual-energy CT (DECT)-based volumetric material decomposition as an indicator for the 2-year occurrence risk of osteoporosis-associated fractures.

METHODS

L1 of 92 patients (46 men, 46 women; mean age, 64 years, range, 19-103 years) who had undergone third-generation dual-source DECT between 01/2016 and 12/2018 was retrospectively analyzed. For phantomless BMD assessment, dedicated DECT postprocessing software using material decomposition was applied. Digital files of all patients were sighted for 2 years following DECT to obtain the incidence of osteoporotic fractures. Receiver operating characteristic (ROC) analysis was used to calculate cut-off values and logistic regression models were used to determine associations of BMD, sex, and age with the occurrence of osteoporotic fractures.

RESULTS

A DECT-derived BMD cut-off of 93.70 mg/cm3 yielded 85.45% sensitivity and 89.19% specificity for the prediction to sustain one or more osteoporosis-associated fractures within 2 years after BMD measurement. DECT-derived BMD was significantly associated with the occurrence of new fractures (odds ratio of 0.8710, 95% CI, 0.091-0.9375, p < .001), indicating a protective effect of increased DECT-derived BMD values. Overall AUC was 0.9373 (CI, 0.867-0.977, p < .001) for the differentiation of patients who sustained osteoporosis-associated fractures within 2 years of BMD assessment.

CONCLUSIONS

Retrospective DECT-based volumetric BMD assessment can accurately predict the 2-year risk to sustain an osteoporosis-associated fracture in at-risk patients without requiring a calibration phantom. Lower DECT-based BMD values are strongly associated with an increased risk to sustain fragility fractures.

KEY POINTS: •Dual-energy CT-derived assessment of bone mineral density can identify patients at risk to sustain osteoporosis-associated fractures with a sensitivity of 85.45% and a specificity of 89.19%. •The DECT-derived BMD threshold for identification of at-risk patients lies above the American College of Radiology (ACR) QCT guidelines for the identification of osteoporosis (93.70 mg/cm3 vs 80 mg/cm3).

Для цитирования: Gruenewald Leon D, Koch Vitali, Martin Simon S, Yel Ibrahim, Eichler Katrin, Gruber-Rouh Tatjana, Lenga Lukas, Wichmann Julian L, Alizadeh Leona S, Albrecht Moritz H, Mader Christoph, Huizinga Nicole A, D'Angelo Tommaso, Mazziotti Silvio, Wesarg Stefan, Vogl Thomas J, Booz Christian. Diagnostic accuracy of quantitative dual-energy CT-based volumetric bone mineral density assessment for the prediction of osteoporosis-associated fractures.. European radiology. 2021. DOI: 10.1007/s00330-021-08323-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.