Scapulothoracic penetration of a Beath pin: an unusual complication of arthroscopic Bankart suture repair.

Shea K P, Lovallo J L

Клинический случайСтатьяПеревод в очереди

Аннотация

The arthroscopic Bankart suture repair technique is an alternative to open procedures that control anterior shoulder instability. A case is presented in which a Beath pin traveled through the scapula and penetrated the scapulothoracic articulation during arthroscopic Bankart repair. The authors caution that strict adherence to Morgan's technique should minimize complications with this procedure.

Для цитирования: Shea K P, Lovallo J L. Scapulothoracic penetration of a Beath pin: an unusual complication of arthroscopic Bankart suture repair.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 1991. DOI: 10.1016/0749-8063(91)90091-b.