Integrated microscale immiscible phase extraction and isothermal amplification for colorimetric detection of Neisseria gonorrhoeae.

Rodriguez-Mateos Pablo, Ngamsom Bongkot, Ameyo Daglus, Wakaba Patrick, Shiluli Clement, Iles Alexander, Gitaka Jesse, Pamme Nicole

СтатьяПеревод в очереди

Аннотация

Gonorrhea is the second most common sexually transmitted infection (STI) with around 87 million cases worldwide estimated in 2016 by the World Health Organization. With over half of the cases being asymptomatic, potential life-threatening complications and increasing numbers of drug-resistant strains, routine monitoring of prevalence and incidence of infections are key preventive measures. Whilst gold standard qPCR tests have excellent accuracy, they are neither affordable nor accessible in low-resource settings. In this study, we developed a lab-on-a-chip platform based on microscale immiscible filtration to extract, concentrate and purify Neisseria gonorrhoeae DNA with an integrated detection assay based on colorimetric isothermal amplification. The platform was capable of detecting as low as 500 copies/mL from spiked synthetic urine and showed no cross-reactivity when challenged with DNAs from other common STIs. The credit card-size device allows DNA extraction and purification without power or centrifuges, and the detection reaction only needs a low-tech block heater, providing a straightforward and visual positive/negative result within 1 h. These advantages offer great potential for accurate, affordable and accessible monitoring of gonorrhea infection in resource-poor settings.

Для цитирования: Rodriguez-Mateos Pablo, Ngamsom Bongkot, Ameyo Daglus, Wakaba Patrick, Shiluli Clement, Iles Alexander, Gitaka Jesse, Pamme Nicole. Integrated microscale immiscible phase extraction and isothermal amplification for colorimetric detection of Neisseria gonorrhoeae.. Analytical and bioanalytical chemistry. 2023. DOI: 10.1007/s00216-023-04734-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.