Should unstable extra-articular distal radial fractures be treated with fixed-angle volar-locked plates or percutaneous Kirschner wires? A prospective randomised controlled trial.

McFadyen I, Field J, McCann P, Ward J, Nicol S, Curwen C

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод в очереди

Аннотация

Fractures of the distal radius are commonly treated with cast immobilisation; however, those potentially unstable injuries with dorsal comminution may need operative intervention. This intervention is usually with manipulation and Kirschner wires but advances in locking-plate technology have enabled surgeons to achieve anatomical reconstruction of complex fracture patterns, even in poor-quality osteoporotic bone.To ascertain if fixed-angle volar-locked plates confer a significant benefit over manipulation and Kirschner-wire stabilisation, we prospectively randomised 56 adult patients with isolated, closed,unilateral, unstable extra-articular fractures into two treatment groups, one fixed with K-wires and the other fixed with a volar locking plate.Functional outcomes were assessed using Gartland and Werley and Disabilities of the Arm, Shoulder and Hand (DASH) scores. These were statistically better in the plate group at 3 and 6 months.Radiological assessment showed statistically better results at 6 weeks, 3 months and 6 months, postoperatively.In the plate group, there was no significant loss of fracture reduction.

Для цитирования: McFadyen I, Field J, McCann P, Ward J, Nicol S, Curwen C. Should unstable extra-articular distal radial fractures be treated with fixed-angle volar-locked plates or percutaneous Kirschner wires? A prospective randomised controlled trial.. Injury. 2011. DOI: 10.1016/j.injury.2010.07.236.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.