Медицинская библиотека · Mutation research. Genetic toxicology and environmental mutagenesis · 2026

In Vivo micronucleus assay: Increased efficiency with an automated imaging system.

Back Seng-Min, Kim Da Yeon, Bin Yi Ho, Jeung Na-Young, Kim Nan-Young, Park Seong-Hoon

СтатьяПеревод в очереди

Аннотация

The in vivo erythrocyte micronucleus (MN) test is a standard assay for detecting chromosomal damage; however, conventional manual scoring is labor-intensive and subject to inter-scorer variability. Although automated image-based scoring offers a practical alternative, its application to bone marrow analysis requires effective enrichment of erythrocytes, to reduce interference from non-target nucleated cells. We have established and validated an automated bone marrow MN scoring workflow, using the Metafer slide-scanning system and associated software platform. We have compared a conventional cellulose column-based enrichment method with a syringe-filter-based method. The filter method reduced residual non-erythroid cellular components more effectively than the column method, although both methods yielded preparations suitable for automated analysis. Automated scoring showed no significant differences from manual microscopy in MN frequency or polychromatic erythrocyte ratio, in either negative- or positive-control groups. Repeated analysis of the same slide demonstrated high repeatability. Automated and manual MN frequencies showed positive linear correlations in both column- and filter-enriched preparations, and Bland-Altman analysis showed overall agreement between the two scoring methods. Automated historical control data (HCD) generated from male and female rats and mice were comparable to manually established laboratory HCD. These findings demonstrate that automated image-based scoring combined with appropriate erythrocyte enrichment is a reliable and practical alternative to conventional manual scoring in the in vivo bone marrow MN assay and may improve analytical efficiency, objectivity, and reproducibility in genotoxicity testing.

Для цитирования: Back Seng-Min, Kim Da Yeon, Bin Yi Ho, Jeung Na-Young, Kim Nan-Young, Park Seong-Hoon. In Vivo micronucleus assay: Increased efficiency with an automated imaging system.. Mutation research. Genetic toxicology and environmental mutagenesis. 2026. DOI: 10.1016/j.mrgentox.2026.503959.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.